變電站sf6泄漏報警器監控主機價格

本系統采用間歇(xie)式檢測模式,進(jin)行(xing)(xing)在(zai)(zai)線監(jian)(jian)測其(qi)場所(suo)(suo)內SF6氣(qi)(qi)體濃度及O2含量和環境溫(wen)度、濕度的狀(zhuang)態(tai)(tai)監(jian)(jian)測,當場所(suo)(suo)內SF6濃度及O2含量和環境濕度發(fa)生變化時(shi)(shi),傳感器立(li)即(ji)響應這些變化。實(shi)現對場所(suo)(suo)內SF6濃度及O2的含量和環境溫(wen)度、濕度進(jin)行(xing)(xing)有效地監(jian)(jian)測。通過(guo)現場總(zong)線(RS485)由監(jian)(jian)控(kong)報警主機(ji)采集狀(zhuang)態(tai)(tai)參數(shu)(shu),當場所(suo)(suo)內出現超限值(zhi)時(shi)(shi),進(jin)入預(yu)警聲光報警同時(shi)(shi)啟(qi)動(dong)(dong)風機(ji)進(jin)行(xing)(xing)通風換氣(qi)(qi)或啟(qi)動(dong)(dong)除濕機(ji)進(jin)行(xing)(xing)除濕。同時(shi)(shi)將(jiang)狀(zhuang)態(tai)(tai)參數(shu)(shu)上(shang)傳輸給(gei)監(jian)(jian)控(kong)中心(xin)。在(zai)(zai)監(jian)(jian)控(kong)中心(xin)電(dian)子(zi)地圖(tu)上(shang)進(jin)行(xing)(xing)定位及管理和環境參量超過(guo)預(yu)設(she)值(zhi)時(shi)(shi)發(fa)出視聽(ting)告警在(zai)(zai)電(dian)子(zi)地圖(tu)界面(mian)上(shang)閃爍顯示,按照預(yu)設(she)置聯動(dong)(dong)方(fang)案(an),對通道門體、風機(ji)以(yi)及水(shui)泵(beng)等(deng)進(jin)行(xing)(xing)管理;以(yi)及通過(guo)語音、短(duan)信方(fang)式自(zi)動(dong)(dong)通知值(zhi)班(ban)維護人員

雙(shuang)氣體檢測器主(zhu)要由傳(chuan)(chuan)感(gan)器、單(dan)片(pian)機(ji)、運(yun)算放大電路(lu)、通(tong)訊芯片(pian)等組成(cheng)。傳(chuan)(chuan)感(gan)器將氣體濃度(du)轉(zhuan)換(huan)為(wei)(wei)模擬(ni)電信(xin)號,然后將模擬(ni)電信(xin)號通(tong)過運(yun)算放大電路(lu)、單(dan)片(pian)機(ji)轉(zhuan)換(huan)為(wei)(wei)數(shu)字信(xin)號,后通(tong)過通(tong)訊芯片(pian)轉(zhuan)換(huan)為(wei)(wei)modbus RTU標(biao)準信(xin)號,上傳(chuan)(chuan)給控(kong)制器。

DX6000H型SF6 在(zai)線(xian)(xian)監測(ce)報(bao)警系統適用(yong)(yong)于(yu)配電室、開關站、光伏發電廠(chang)、海上風電場、10KV、35KV、220KV開關柜、GIS室等場所(suo);設備(bei)監測(ce)精度高、范圍廣(guang)、功(gong)能全,具有(you)(you)良(liang)好(hao)的(de)擴展性 2.1 采用(yong)(yong)1024*600觸(chu)摸屏,全中文菜單操作(zuo),界面友(you)好(hao),操作(zuo)簡單; 2.2 設備(bei)集(ji)成三組485接(jie)口(kou),采用(yong)(yong)插(cha)拔式接(jie)線(xian)(xian)端子(zi)接(jie)線(xian)(xian)簡單,具有(you)(you)良(liang)好(hao)的(de)抗干擾能力,總線(xian)(xian)通訊,布線(xian)(xian)經(jing)濟,安裝方便(bian); 2.3 三組DC24V接(jie)口(kou),可選配DC3.3V、DC5V、DC12V電壓輸出, 2.4 自(zi)動(dong)故障檢測(ce),并能用(yong)(yong)中文顯示處準(zhun)確的(de)故障部位(wei)及(ji)類型; 2.5 自(zi)動(dong)檢索(suo)探(tan)測(ce)器(qi)地址及(ji)狀態,SF6/O2/溫濕(shi)度探(tan)測(ce)器(qi)在(zai)同(tong)一系統監控; 2.6 大容量儲存(cun)芯片(pian),循(xun)環(huan)記錄(lu)(lu)報(bao)警信息,大可記錄(lu)(lu)50000條(tiao); 2.7 RS485上傳接(jie)口(kou),標準(zhun)modbus Rtu通訊協議。

2.8 關鍵參(can)數(shu)(shu),加密設(she)定,防止誤(wu)操作 2.9 多可選配7組(zu)繼電(dian)器,繼電(dian)器控制方式(shi)(shi)可軟件(jian)設(she)置(zhi)(zhi) 2.10 具(ju)有(you) 年-月-日(ri)-時(shi)(shi)-分-秒(miao)設(she)置(zhi)(zhi)功(gong)(gong)能,并且帶有(you)每(mei)周(zhou)七(qi)天(tian)分別(bie)顯(xian)(xian)示(shi)(shi)功(gong)(gong)能 壁(bi)掛式(shi)(shi)SF6氣(qi)(qi)體(ti)報(bao)(bao)(bao)(bao)(bao)(bao)警主(zhu)機_SF6氧氣(qi)(qi)一體(ti)式(shi)(shi)探測(ce)器_SF6泄漏在線(xian)(xian)監測(ce)報(bao)(bao)(bao)(bao)(bao)(bao)警系統_SF6氣(qi)(qi)體(ti)在線(xian)(xian)監測(ce)報(bao)(bao)(bao)(bao)(bao)(bao)警裝置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)在線(xian)(xian)監測(ce)報(bao)(bao)(bao)(bao)(bao)(bao)警系統 三章:主(zhu)要技術指標 3.1 壁(bi)掛式(shi)(shi)主(zhu)機技術指標(DX6000H型) 3.1.1 工(gong)作電(dian)壓: AC220V±15%,50Hz±1% 3.1.2 信號輸(shu)(shu)出: RS485 modbus_RTU 協議(yi)輸(shu)(shu)出 3.1.3 工(gong)作溫(wen)度(du): -20℃~+55℃ 3.1.4 工(gong)作濕度(du): ≤93%RH 3.1.5 顯(xian)(xian)示(shi)(shi)方式(shi)(shi): 列表顯(xian)(xian)示(shi)(shi),每(mei)頁(ye)顯(xian)(xian)示(shi)(shi)8組(zu)或10組(zu)數(shu)(shu)據(ju)(每(mei)組(zu)包括(kuo)SF6/02/溫(wen)度(du)/濕度(du)四種(zhong)數(shu)(shu)據(ju)和兩(liang)種(zhong)數(shu)(shu)據(ju)狀態(tai)) 3.1.6 上(shang)傳參(can)數(shu)(shu): 默(mo)認(ren)ID 1(可調(diao)),默(mo)認(ren)波特率(lv)9600(可調(diao)) 3.1.7 人(ren)體(ti)感應:默(mo)認(ren)開啟(qi)(qi)感應亮(liang)屏(ping)功(gong)(gong)能 3.1.8 屏(ping)幕(mu)保護:默(mo)認(ren)開啟(qi)(qi)亮(liang)屏(ping)5分鐘后自動(dong)(dong)息屏(ping),人(ren)體(ti)感應或觸摸可亮(liang)屏(ping) 3.1.9 排(pai)風功(gong)(gong)能:自動(dong)(dong)排(pai)風,定時(shi)(shi)排(pai)風,手動(dong)(dong)排(pai)風,延時(shi)(shi)排(pai)風,手動(dong)(dong)排(pai)風可設(she)置(zhi)(zhi)低1s,大12H,自動(dong)(dong)排(pai)風分為12組(zu),可設(she)置(zhi)(zhi)開啟(qi)(qi)組(zu)數(shu)(shu)、開啟(qi)(qi)日(ri)期、開啟(qi)(qi)時(shi)(shi)間(jian)及啟(qi)(qi)動(dong)(dong)時(shi)(shi)間(jian)(啟(qi)(qi)動(dong)(dong)時(shi)(shi)間(jian)可更改(gai))功(gong)(gong)能 sf6氣(qi)(qi)體(ti)報(bao)(bao)(bao)(bao)(bao)(bao)警裝置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)報(bao)(bao)(bao)(bao)(bao)(bao)警器_SF6報(bao)(bao)(bao)(bao)(bao)(bao)警裝置(zhi)(zhi)_SF6報(bao)(bao)(bao)(bao)(bao)(bao)警主(zhu)機_SF6報(bao)(bao)(bao)(bao)(bao)(bao)警器。

SF6行(xing)業安全法規摘錄 ■191條 裝(zhuang)(zhuang)有SF6設(she)(she)備(bei)的配(pei)電(dian)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)室和(he)SF6氣體實(shi)驗室,必須裝(zhuang)(zhuang)設(she)(she)強力通(tong)風(feng)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)。風(feng)口(kou)應(ying)設(she)(she)置(zhi)(zhi)(zhi)在(zai)室內低部。■192條 在(zai)室內,設(she)(she)備(bei)充(chong)裝(zhuang)(zhuang)SF6氣體時,周(zhou)圍環境(jing)相對濕度應(ying)≤80%,同時必須開啟(qi)通(tong)風(feng)系統,并(bing)避(bi)免SF6氣體漏泄到(dao)工作區(qu)。工作區(qu)空氣中SF6氣體含(han)量不得(de)超過1000ppm。■196條 工作人員進(jin)(jin)入SF6配(pei)電(dian)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)室,必須先通(tong)風(feng)15min,并(bing)用(yong)檢漏儀(yi)測量SF6氣體含(han)量。盡量避(bi)免一(yi)人進(jin)(jin)入SF6配(pei)電(dian)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)室進(jin)(jin)行(xing)巡(xun)視,不準(zhun)一(yi)人進(jin)(jin)入從(cong)事檢修工作。■198條 進(jin)(jin)入SF6配(pei)電(dian)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)室低位區(qu)或電(dian)纜溝進(jin)(jin)行(xing)工作應(ying)先檢測含(han)氧量(不低于18%)和(he)SF6氣體含(han)量是否(fou)合格