久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱線電話:15376190119
您所在的位置: 主頁 ? 新聞動態

光伏站sf6泄漏報警裝置主機批發

發布時間:2023-11-20 09:52:20       發布人:dxdz  瀏覽量:

光伏站sf6泄漏報警裝置主機批發

本系統(tong)采用間(jian)歇式(shi)檢測模(mo)式(shi),進(jin)行(xing)在線監(jian)(jian)測其場(chang)所(suo)內(nei)SF6氣(qi)(qi)體濃度(du)(du)(du)(du)(du)及(ji)O2含(han)量和環(huan)境溫度(du)(du)(du)(du)(du)、濕(shi)(shi)度(du)(du)(du)(du)(du)的(de)狀態(tai)監(jian)(jian)測,當場(chang)所(suo)內(nei)SF6濃度(du)(du)(du)(du)(du)及(ji)O2含(han)量和環(huan)境濕(shi)(shi)度(du)(du)(du)(du)(du)發(fa)(fa)生變化時,傳感器立即(ji)響應這些變化。實現(xian)對場(chang)所(suo)內(nei)SF6濃度(du)(du)(du)(du)(du)及(ji)O2的(de)含(han)量和環(huan)境溫度(du)(du)(du)(du)(du)、濕(shi)(shi)度(du)(du)(du)(du)(du)進(jin)行(xing)有效地監(jian)(jian)測。通過現(xian)場(chang)總線(RS485)由監(jian)(jian)控(kong)報(bao)警主機(ji)采集狀態(tai)參(can)數,當場(chang)所(suo)內(nei)出現(xian)超(chao)限值(zhi)時,進(jin)入預警聲光報(bao)警同(tong)時啟動(dong)(dong)風(feng)機(ji)進(jin)行(xing)通風(feng)換氣(qi)(qi)或啟動(dong)(dong)除濕(shi)(shi)機(ji)進(jin)行(xing)除濕(shi)(shi)。同(tong)時將狀態(tai)參(can)數上傳輸給(gei)監(jian)(jian)控(kong)中(zhong)心(xin)。在監(jian)(jian)控(kong)中(zhong)心(xin)電子(zi)地圖(tu)上進(jin)行(xing)定位及(ji)管理和環(huan)境參(can)量超(chao)過預設值(zhi)時發(fa)(fa)出視聽(ting)告警在電子(zi)地圖(tu)界面(mian)上閃爍顯示,按照預設置聯動(dong)(dong)方案,對通道門體、風(feng)機(ji)以及(ji)水泵等進(jin)行(xing)管理;以及(ji)通過語(yu)音(yin)、短信方式(shi)自動(dong)(dong)通知(zhi)值(zhi)班(ban)維護(hu)人員

雙氣體(ti)(ti)檢測(ce)器主要由傳(chuan)感(gan)器、單(dan)片(pian)機(ji)、運算放(fang)大電(dian)(dian)路、通(tong)訊(xun)(xun)芯(xin)片(pian)等組成(cheng)。傳(chuan)感(gan)器將氣體(ti)(ti)濃度轉(zhuan)(zhuan)換(huan)為(wei)模(mo)擬(ni)電(dian)(dian)信號,然后將模(mo)擬(ni)電(dian)(dian)信號通(tong)過運算放(fang)大電(dian)(dian)路、單(dan)片(pian)機(ji)轉(zhuan)(zhuan)換(huan)為(wei)數(shu)字信號,后通(tong)過通(tong)訊(xun)(xun)芯(xin)片(pian)轉(zhuan)(zhuan)換(huan)為(wei)modbus RTU標準信號,上傳(chuan)給(gei)控(kong)制器。

DX6000H型(xing)SF6 在線(xian)(xian)監測(ce)(ce)報(bao)(bao)警(jing)系(xi)統(tong)適用(yong)(yong)于配電室、開關站、光伏(fu)發電廠、海上(shang)風電場(chang)、10KV、35KV、220KV開關柜、GIS室等場(chang)所;設(she)備監測(ce)(ce)精度(du)高(gao)、范圍廣、功能全(quan),具有良好的擴展性 2.1 采用(yong)(yong)1024*600觸摸屏,全(quan)中文菜單操(cao)作,界面友(you)好,操(cao)作簡單; 2.2 設(she)備集(ji)成三組(zu)485接(jie)口(kou),采用(yong)(yong)插拔式接(jie)線(xian)(xian)端子接(jie)線(xian)(xian)簡單,具有良好的抗干擾能力,總線(xian)(xian)通訊,布線(xian)(xian)經濟,安裝方便(bian); 2.3 三組(zu)DC24V接(jie)口(kou),可(ke)選(xuan)配DC3.3V、DC5V、DC12V電壓輸出, 2.4 自動故(gu)障檢(jian)測(ce)(ce),并能用(yong)(yong)中文顯示處準確的故(gu)障部位及類型(xing); 2.5 自動檢(jian)索(suo)探測(ce)(ce)器(qi)地(di)址(zhi)及狀態,SF6/O2/溫濕(shi)度(du)探測(ce)(ce)器(qi)在同一系(xi)統(tong)監控; 2.6 大容量(liang)儲存芯片,循環記(ji)錄報(bao)(bao)警(jing)信息(xi),大可(ke)記(ji)錄50000條; 2.7 RS485上(shang)傳接(jie)口(kou),標準modbus Rtu通訊協議。

2.8 關鍵參(can)數,加密(mi)設定,防止誤(wu)操(cao)作 2.9 多可(ke)選配7組(zu)繼電器(qi),繼電器(qi)控制方式(shi)可(ke)軟件(jian)設置(zhi)(zhi) 2.10 具有(you) 年-月(yue)-日-時-分-秒設置(zhi)(zhi)功(gong)能(neng)(neng),并且帶有(you)每周七天(tian)分別(bie)顯(xian)示(shi)功(gong)能(neng)(neng) 壁掛(gua)式(shi)SF6氣(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)主(zhu)機_SF6氧氣(qi)(qi)一體(ti)(ti)(ti)式(shi)探測器(qi)_SF6泄漏在(zai)線(xian)(xian)(xian)監測報(bao)(bao)警(jing)(jing)系(xi)統_SF6氣(qi)(qi)體(ti)(ti)(ti)在(zai)線(xian)(xian)(xian)監測報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)(ti)(ti)在(zai)線(xian)(xian)(xian)監測報(bao)(bao)警(jing)(jing)系(xi)統 三章(zhang):主(zhu)要技術指標 3.1 壁掛(gua)式(shi)主(zhu)機技術指標(DX6000H型) 3.1.1 工作電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸出(chu): RS485 modbus_RTU 協議輸出(chu) 3.1.3 工作溫(wen)度(du)(du)(du)(du): -20℃~+55℃ 3.1.4 工作濕度(du)(du)(du)(du): ≤93%RH 3.1.5 顯(xian)示(shi)方式(shi): 列表顯(xian)示(shi),每頁顯(xian)示(shi)8組(zu)或(huo)10組(zu)數據(ju)(每組(zu)包括SF6/02/溫(wen)度(du)(du)(du)(du)/濕度(du)(du)(du)(du)四種數據(ju)和兩種數據(ju)狀(zhuang)態) 3.1.6 上傳參(can)數: 默(mo)認ID 1(可(ke)調(diao)),默(mo)認波特率9600(可(ke)調(diao)) 3.1.7 人(ren)體(ti)(ti)(ti)感應:默(mo)認開啟(qi)感應亮屏(ping)功(gong)能(neng)(neng) 3.1.8 屏(ping)幕保護:默(mo)認開啟(qi)亮屏(ping)5分鐘后自(zi)動(dong)息(xi)屏(ping),人(ren)體(ti)(ti)(ti)感應或(huo)觸摸可(ke)亮屏(ping) 3.1.9 排(pai)(pai)(pai)(pai)(pai)風(feng)功(gong)能(neng)(neng):自(zi)動(dong)排(pai)(pai)(pai)(pai)(pai)風(feng),定時排(pai)(pai)(pai)(pai)(pai)風(feng),手動(dong)排(pai)(pai)(pai)(pai)(pai)風(feng),延時排(pai)(pai)(pai)(pai)(pai)風(feng),手動(dong)排(pai)(pai)(pai)(pai)(pai)風(feng)可(ke)設置(zhi)(zhi)低1s,大12H,自(zi)動(dong)排(pai)(pai)(pai)(pai)(pai)風(feng)分為12組(zu),可(ke)設置(zhi)(zhi)開啟(qi)組(zu)數、開啟(qi)日期、開啟(qi)時間及啟(qi)動(dong)時間(啟(qi)動(dong)時間可(ke)更(geng)改(gai))功(gong)能(neng)(neng)  sf6氣(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)器(qi)_SF6報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)(zhi)_SF6報(bao)(bao)警(jing)(jing)主(zhu)機_SF6報(bao)(bao)警(jing)(jing)器(qi)。

SF6行(xing)(xing)業安全法規(gui)摘錄 ■191條 裝(zhuang)有SF6設(she)備的配(pei)電裝(zhuang)置(zhi)(zhi)(zhi)室(shi)(shi)和SF6氣體(ti)(ti)實驗室(shi)(shi),必(bi)(bi)須裝(zhuang)設(she)強力通(tong)風(feng)裝(zhuang)置(zhi)(zhi)(zhi)。風(feng)口應設(she)置(zhi)(zhi)(zhi)在室(shi)(shi)內低部。■192條 在室(shi)(shi)內,設(she)備充裝(zhuang)SF6氣體(ti)(ti)時,周圍環(huan)境相對濕度(du)應≤80%,同時必(bi)(bi)須開啟通(tong)風(feng)系統,并避(bi)免SF6氣體(ti)(ti)漏泄到(dao)工(gong)作(zuo)區(qu)。工(gong)作(zuo)區(qu)空(kong)氣中SF6氣體(ti)(ti)含量(liang)不得超過1000ppm。■196條 工(gong)作(zuo)人員進(jin)入SF6配(pei)電裝(zhuang)置(zhi)(zhi)(zhi)室(shi)(shi),必(bi)(bi)須先(xian)通(tong)風(feng)15min,并用檢漏儀測量(liang)SF6氣體(ti)(ti)含量(liang)。盡量(liang)避(bi)免一(yi)人進(jin)入SF6配(pei)電裝(zhuang)置(zhi)(zhi)(zhi)室(shi)(shi)進(jin)行(xing)(xing)巡視,不準(zhun)一(yi)人進(jin)入從事(shi)檢修工(gong)作(zuo)。■198條 進(jin)入SF6配(pei)電裝(zhuang)置(zhi)(zhi)(zhi)室(shi)(shi)低位區(qu)或電纜溝進(jin)行(xing)(xing)工(gong)作(zuo)應先(xian)檢測含氧(yang)量(liang)(不低于18%)和SF6氣體(ti)(ti)含量(liang)是否合格

光伏站sf6泄漏報警裝置主機批發 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6泄漏報警裝置主機批發

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地址:濟南市高新技術開(kai)發(fa)區(qu)花(hua)園路(lu)東首

電話:15376190119

郵箱:sddx0001@163.com