可燃氣體報警器公司_技術支持_燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子
可(ke)燃氣體(ti)報警器(qi)公(gong)司可(ke)燃氣體(ti)報警器(qi)主要(yao)有催(cui)化燃燒(shao)(shao)型(xing)(xing)、熱導(dao)(dao)型(xing)(xing)、紅外吸收(shou)型(xing)(xing)和半導(dao)(dao)體(ti)型(xing)(xing)等(deng)幾種,其(qi)中(zhong)使用最廣泛的是催(cui)化燃燒(shao)(shao)型(xing)(xing)。催(cui)化燃燒(shao)(shao)型(xing)(xing)報警器(qi)傳感(gan)器(qi)主要(yao)是由(you)橋式電(dian)(dian)(dian)路(lu)、氣敏原件組成。當可(ke)燃氣體(ti)進入報警器(qi)探頭(tou),氣體(ti)與(yu)空氣中(zhong)的氧(yang)發生(sheng)氧(yang)化反應,鉑(bo)(bo)絲表面(mian)產生(sheng)無煙催(cui)化燃燒(shao)(shao),導(dao)(dao)致鉑(bo)(bo)絲升(sheng)溫,鉑(bo)(bo)絲是感(gan)溫原件,電(dian)(dian)(dian)阻值隨溫度升(sheng)高而增長,橋式電(dian)(dian)(dian)路(lu)失去平衡(heng),產生(sheng)電(dian)(dian)(dian)流(liu),即將氣體(ti)濃度值轉換為電(dian)(dian)(dian)信號輸(shu)出。報警器(qi)由(you)探測器(qi)和控(kong)(kong)制(zhi)(zhi)器(qi)兩部(bu)分組成,探測器(qi)即探頭(tou)傳感(gan)器(qi)部(bu)分,將氣體(ti)濃度轉換成電(dian)(dian)(dian)信號,控(kong)(kong)制(zhi)(zhi)器(qi)包括控(kong)(kong)制(zhi)(zhi)電(dian)(dian)(dian)路(lu)、放(fang)大電(dian)(dian)(dian)路(lu)、報警系統(tong)和顯示器(qi)等(deng)部(bu)分。
技術參數
認證
◆ 消防電子產品合格評定中心
◆ 應用標準:GB16808(2008
電氣
◆ 供電電源:195~235VAC/50~60Hz
◆ 控制輸出:繼電器AC220V/5A(2個無源常開常閉點)
◆ 接線端子:適合導線截面積0.5(2.5mm2
◆ 接線方式:兩線制2*2.5mm2
結構
◆ 安裝方式:壁掛、盤裝式或機柜式
◆ 重 量:≤3.5kg
環境
◆ 工作溫度:(20℃~60℃
◆ 工作濕度:≤95%RH(無凝露)
◆ 壓力范圍:86~106kPa
◆ 傳輸距離:≤1200m
顯示報警
◆ 顯示單位:(易燃易爆氣體)為%LEL
(有毒有害氣體)為ppm
◆ 報警方式:聲光報警
◆ 報警音量:≥75dB
◆ 供電電源:DC36V±15%
◆ 最大功率:<1W
◆ 通訊方式:M-BUS 總線
◆ 信號輸出:一組無源常開信號
◆ 連接線纜:RVS 2×2.5mm2
◆ 準 確 度:±5%FS
◆ 分辨率:1%ppm
◆ 檢測原理:紅外式
◆ 響應時間:紅外式 T90<90s
可燃氣體報警器公司
地址:濟(ji)南市高(gao)新技術(shu)開發區(qu)花園(yuan)路東(dong)首
電話:15376190119
郵(you)箱:sddx0001@163.com