久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱(re)線電話:15376190119
您所在的位置: 主頁 ? 技術支持

光伏站sf6氣體報警裝置探測主機安裝

發布時間:2023-11-09 19:41:55       發布人:dxdz  瀏覽量:

光伏站sf6氣體報警裝置探測主機安裝

SF6氣(qi)(qi)(qi)體(ti)泄漏監(jian)(jian)控子系(xi)(xi)統主(zhu)要對SF6氣(qi)(qi)(qi)體(ti)為絕緣介(jie)質(zhi)的高(gao)壓電(dian)器(qi)(qi)(qi)設備(bei)場(chang)所內(nei)進行(xing)環境(jing)監(jian)(jian)測。當場(chang)所內(nei)設備(bei)發(fa)生(sheng)SF6氣(qi)(qi)(qi)體(ti)泄漏時(shi),由于SF6氣(qi)(qi)(qi)體(ti)的密(mi)度(du)(du)是空氣(qi)(qi)(qi)的5倍,積累于底(di)層空間,并造成局部缺氧(yang),引起嚴重(zhong)事(shi)故。為此:《電(dian)業(ye)安全工(gong)作規程》(發(fa)電(dian)廠和(he)變電(dian)站部分)特別規定,工(gong)作人(ren)員進入SF6配電(dian)裝置室低位(wei)區或電(dian)纜溝(gou)進行(xing)工(gong)作必須保證SF6氣(qi)(qi)(qi)體(ti)濃度(du)(du)小于1000ppm,含(han)氧(yang)量不低于18%及周圍環境(jing)相對濕(shi)度(du)(du)80%,同(tong)時(shi)必須開啟通(tong)風系(xi)(xi)統。SF6+O2雙(shuang)氣(qi)(qi)(qi)體(ti)探(tan)測器(qi)(qi)(qi)_SF6+O2氣(qi)(qi)(qi)體(ti)探(tan)測器(qi)(qi)(qi)_SF6+O2探(tan)測器(qi)(qi)(qi)_SF6+O2雙(shuang)氣(qi)(qi)(qi)體(ti)探(tan)頭_SF6+O2氣(qi)(qi)(qi)體(ti)探(tan)頭_sf6氣(qi)(qi)(qi)體(ti)檢測儀

主(zhu)要功(gong)能(neng)(neng)監控報(bao)(bao)警(jing)主(zhu)機(ji)主(zhu)要用于(yu)對(dui)下采集實(shi)時數(shu)(shu)據(ju)(ju)(包括(kuo)控制(zhi)器在內),對(dui)這些數(shu)(shu)據(ju)(ju)進行(xing)(xing)分析(xi)和(he)(he)管(guan)理,具(ju)有(you)判斷現場(chang)數(shu)(shu)據(ju)(ju)是否超出(chu)設定(ding)(ding)報(bao)(bao)警(jing)閥值(zhi)的功(gong)能(neng)(neng),超出(chu)則(ze)進行(xing)(xing)報(bao)(bao)警(jing)輸出(chu),啟(qi)(qi)動(dong)風機(ji)進行(xing)(xing)通(tong)風或啟(qi)(qi)動(dong)除濕進行(xing)(xing)除濕,同時聲(sheng)光報(bao)(bao)警(jing)器進入(ru)報(bao)(bao)警(jing)狀(zhuang)態,并(bing)能(neng)(neng)接(jie)收入(ru)口處(chu)人員入(ru)室(shi)啟(qi)(qi)動(dong)風機(ji)進行(xing)(xing)通(tong)風的功(gong)能(neng)(neng)。并(bing)可(ke)隨時接(jie)收一體化信息平臺的訪問(wen); 監控報(bao)(bao)警(jing)主(zhu)機(ji)的液晶顯(xian)示(shi)屏(ping)顯(xian)示(shi)現場(chang)實(shi)時數(shu)(shu)據(ju)(ju)、歷史數(shu)(shu)據(ju)(ju)、歷史報(bao)(bao)警(jing)數(shu)(shu)據(ju)(ju)和(he)(he)報(bao)(bao)警(jing)時間(jian)等各種(zhong)(zhong)參(can)數(shu)(shu);還可(ke)采用鍵盤/觸模屏(ping)實(shi)現項目設置(zhi)、時間(jian)設置(zhi)、閥值(zhi)設置(zhi)、定(ding)(ding)時采集設置(zhi)、定(ding)(ding)時啟(qi)(qi)動(dong)風機(ji)設置(zhi),還設有(you)人體感應啟(qi)(qi)動(dong)液晶顯(xian)示(shi)屏(ping)背(bei)光及(ji)(ji)語(yu)音播報(bao)(bao)實(shi)時數(shu)(shu)據(ju)(ju)等多種(zhong)(zhong)配置(zhi)和(he)(he)管(guan)理功(gong)能(neng)(neng)。并(bing)能(neng)(neng)支持外置(zhi)顯(xian)示(shi)屏(ping)狀(zhuang)態顯(xian)示(shi)及(ji)(ji)語(yu)音播報(bao)(bao)功(gong)能(neng)(neng);

DX6000H型SF6 在線監(jian)(jian)測報(bao)警系(xi)(xi)統適用(yong)于配(pei)電(dian)室、開(kai)關站、光伏發電(dian)廠(chang)、海上(shang)(shang)風電(dian)場(chang)、10KV、35KV、220KV開(kai)關柜、GIS室等(deng)場(chang)所;設備(bei)監(jian)(jian)測精度(du)(du)高、范圍廣、功能全(quan),具有良好的(de)(de)擴展(zhan)性 2.1 采(cai)用(yong)1024*600觸摸屏,全(quan)中文菜單(dan)操作,界面(mian)友好,操作簡(jian)單(dan); 2.2 設備(bei)集成三組(zu)485接(jie)口(kou),采(cai)用(yong)插拔式接(jie)線端子接(jie)線簡(jian)單(dan),具有良好的(de)(de)抗干擾(rao)能力(li),總線通(tong)訊(xun),布(bu)線經濟,安(an)裝方便(bian); 2.3 三組(zu)DC24V接(jie)口(kou),可選配(pei)DC3.3V、DC5V、DC12V電(dian)壓輸出, 2.4 自動故障(zhang)檢測,并(bing)能用(yong)中文顯(xian)示處(chu)準(zhun)確的(de)(de)故障(zhang)部位及(ji)類型; 2.5 自動檢索探測器(qi)地址及(ji)狀態(tai),SF6/O2/溫(wen)濕度(du)(du)探測器(qi)在同一(yi)系(xi)(xi)統監(jian)(jian)控; 2.6 大容量(liang)儲存芯(xin)片,循環記錄(lu)報(bao)警信息,大可記錄(lu)50000條; 2.7 RS485上(shang)(shang)傳接(jie)口(kou),標準(zhun)modbus Rtu通(tong)訊(xun)協議。

2.8 關鍵(jian)參(can)數(shu),加密設定,防止誤(wu)操作 2.9 多可(ke)(ke)(ke)(ke)選配(pei)7組(zu)繼電器,繼電器控(kong)制(zhi)方(fang)式(shi)(shi)(shi)可(ke)(ke)(ke)(ke)軟(ruan)件(jian)設置(zhi)(zhi) 2.10 具有 年-月-日-時(shi)-分(fen)-秒(miao)設置(zhi)(zhi)功(gong)能(neng),并且帶有每(mei)周(zhou)七天分(fen)別顯示功(gong)能(neng) 壁(bi)掛(gua)式(shi)(shi)(shi)SF6氣(qi)(qi)體(ti)(ti)報(bao)(bao)警(jing)(jing)主(zhu)機_SF6氧(yang)氣(qi)(qi)一(yi)體(ti)(ti)式(shi)(shi)(shi)探測(ce)器_SF6泄(xie)漏在線(xian)(xian)監(jian)測(ce)報(bao)(bao)警(jing)(jing)系(xi)統_SF6氣(qi)(qi)體(ti)(ti)在線(xian)(xian)監(jian)測(ce)報(bao)(bao)警(jing)(jing)裝置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)(ti)在線(xian)(xian)監(jian)測(ce)報(bao)(bao)警(jing)(jing)系(xi)統 三章:主(zhu)要技術指(zhi)標(biao) 3.1 壁(bi)掛(gua)式(shi)(shi)(shi)主(zhu)機技術指(zhi)標(biao)(DX6000H型) 3.1.1 工(gong)作電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸(shu)出: RS485 modbus_RTU 協議輸(shu)出 3.1.3 工(gong)作溫度(du)(du): -20℃~+55℃ 3.1.4 工(gong)作濕度(du)(du): ≤93%RH 3.1.5 顯示方(fang)式(shi)(shi)(shi): 列表顯示,每(mei)頁顯示8組(zu)或(huo)10組(zu)數(shu)據(每(mei)組(zu)包括SF6/02/溫度(du)(du)/濕度(du)(du)四種數(shu)據和(he)兩(liang)種數(shu)據狀態) 3.1.6 上傳參(can)數(shu): 默認(ren)(ren)ID 1(可(ke)(ke)(ke)(ke)調(diao)),默認(ren)(ren)波特率9600(可(ke)(ke)(ke)(ke)調(diao)) 3.1.7 人體(ti)(ti)感應(ying):默認(ren)(ren)開(kai)啟感應(ying)亮(liang)屏功(gong)能(neng) 3.1.8 屏幕(mu)保護:默認(ren)(ren)開(kai)啟亮(liang)屏5分(fen)鐘后自(zi)(zi)動(dong)(dong)(dong)息屏,人體(ti)(ti)感應(ying)或(huo)觸摸可(ke)(ke)(ke)(ke)亮(liang)屏 3.1.9 排(pai)(pai)(pai)風功(gong)能(neng):自(zi)(zi)動(dong)(dong)(dong)排(pai)(pai)(pai)風,定時(shi)排(pai)(pai)(pai)風,手動(dong)(dong)(dong)排(pai)(pai)(pai)風,延時(shi)排(pai)(pai)(pai)風,手動(dong)(dong)(dong)排(pai)(pai)(pai)風可(ke)(ke)(ke)(ke)設置(zhi)(zhi)低1s,大(da)12H,自(zi)(zi)動(dong)(dong)(dong)排(pai)(pai)(pai)風分(fen)為12組(zu),可(ke)(ke)(ke)(ke)設置(zhi)(zhi)開(kai)啟組(zu)數(shu)、開(kai)啟日期、開(kai)啟時(shi)間及啟動(dong)(dong)(dong)時(shi)間(啟動(dong)(dong)(dong)時(shi)間可(ke)(ke)(ke)(ke)更改)功(gong)能(neng) sf6氣(qi)(qi)體(ti)(ti)報(bao)(bao)警(jing)(jing)裝置(zhi)(zhi)_SF6氣(qi)(qi)體(ti)(ti)報(bao)(bao)警(jing)(jing)器_SF6報(bao)(bao)警(jing)(jing)裝置(zhi)(zhi)_SF6報(bao)(bao)警(jing)(jing)主(zhu)機_SF6報(bao)(bao)警(jing)(jing)器。

SF6行(xing)(xing)業(ye)安全法規摘錄 ■191條(tiao) 裝(zhuang)(zhuang)有(you)SF6設(she)備的配(pei)(pei)(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)室和(he)SF6氣(qi)體實驗室,必須(xu)裝(zhuang)(zhuang)設(she)強力通風裝(zhuang)(zhuang)置(zhi)。風口應(ying)設(she)置(zhi)在室內低(di)部。■192條(tiao) 在室內,設(she)備充裝(zhuang)(zhuang)SF6氣(qi)體時,周圍環境相對濕(shi)度應(ying)≤80%,同時必須(xu)開啟通風系統,并避免SF6氣(qi)體漏(lou)(lou)泄到工作(zuo)(zuo)區。工作(zuo)(zuo)區空氣(qi)中SF6氣(qi)體含(han)量(liang)不(bu)得超過1000ppm。■196條(tiao) 工作(zuo)(zuo)人員進(jin)(jin)入SF6配(pei)(pei)(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)室,必須(xu)先通風15min,并用檢漏(lou)(lou)儀測量(liang)SF6氣(qi)體含(han)量(liang)。盡量(liang)避免一人進(jin)(jin)入SF6配(pei)(pei)(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)室進(jin)(jin)行(xing)(xing)巡視,不(bu)準一人進(jin)(jin)入從事檢修工作(zuo)(zuo)。■198條(tiao) 進(jin)(jin)入SF6配(pei)(pei)(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)室低(di)位區或電(dian)(dian)纜溝進(jin)(jin)行(xing)(xing)工作(zuo)(zuo)應(ying)先檢測含(han)氧量(liang)(不(bu)低(di)于18%)和(he)SF6氣(qi)體含(han)量(liang)是(shi)否(fou)合格

光伏站sf6氣體報警裝置探測主機安裝 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6氣體報警裝置探測主機安裝

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地(di)址:濟(ji)南市高新(xin)技術(shu)開(kai)發區花園路東首

電話:15376190119

郵箱:sddx0001@163.com