久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱線電(dian)話(hua):15376190119
您所在的位置: 主頁 ? 新聞動態 ? 行業資訊

變電站sf6氣體檢測儀報警裝置多少錢

發布時間:2023-12-12 21:48:15       發布人:dxdz  瀏覽量:

變電站sf6氣體檢測儀報警裝置多少錢

本系統采用間(jian)歇式(shi)檢測模式(shi),進(jin)行(xing)(xing)在線(xian)監(jian)(jian)測其場所內SF6氣體濃(nong)(nong)度(du)及O2含量和(he)環(huan)境(jing)溫(wen)度(du)、濕(shi)(shi)度(du)的狀態監(jian)(jian)測,當場所內SF6濃(nong)(nong)度(du)及O2含量和(he)環(huan)境(jing)濕(shi)(shi)度(du)發生變化時,傳(chuan)感器立(li)即響應這(zhe)些變化。實(shi)現對場所內SF6濃(nong)(nong)度(du)及O2的含量和(he)環(huan)境(jing)溫(wen)度(du)、濕(shi)(shi)度(du)進(jin)行(xing)(xing)有效地監(jian)(jian)測。通(tong)(tong)過(guo)現場總線(xian)(RS485)由(you)監(jian)(jian)控報(bao)警主機(ji)采集狀態參數(shu),當場所內出(chu)現超(chao)限值(zhi)(zhi)時,進(jin)入預(yu)警聲光報(bao)警同(tong)時啟動風機(ji)進(jin)行(xing)(xing)通(tong)(tong)風換氣或(huo)啟動除(chu)(chu)濕(shi)(shi)機(ji)進(jin)行(xing)(xing)除(chu)(chu)濕(shi)(shi)。同(tong)時將(jiang)狀態參數(shu)上傳(chuan)輸給監(jian)(jian)控中心。在監(jian)(jian)控中心電子地圖上進(jin)行(xing)(xing)定位(wei)及管(guan)(guan)理(li)和(he)環(huan)境(jing)參量超(chao)過(guo)預(yu)設(she)值(zhi)(zhi)時發出(chu)視聽告警在電子地圖界面上閃(shan)爍顯示,按(an)照預(yu)設(she)置聯動方案,對通(tong)(tong)道門體、風機(ji)以(yi)及水泵(beng)等進(jin)行(xing)(xing)管(guan)(guan)理(li);以(yi)及通(tong)(tong)過(guo)語音、短信方式(shi)自動通(tong)(tong)知值(zhi)(zhi)班維(wei)護人員

雙(shuang)氣(qi)體(ti)檢測(ce)器(qi)(qi)主(zhu)(zhu)要由SF6傳感(gan)器(qi)(qi)和O2傳感(gan)器(qi)(qi)、溫濕度傳感(gan)器(qi)(qi)及(ji)CPU主(zhu)(zhu)控電路、通(tong)信模(mo)塊、電源模(mo)塊等集成在一個優質鋁型材一體(ti)化結構(gou)機箱內(nei),完成SF6濃度、O2含量及(ji)溫濕度的檢測(ce)。將(jiang)檢測(ce)結果(guo)采(cai)用(yong)現場總線(xian)(xian)(RS-485)方式傳輸(shu)給監控主(zhu)(zhu)機或PC機進(jin)(jin)行實時顯示。接(jie)線(xian)(xian)方式選用(yong)可插拔(ba)式接(jie)線(xian)(xian)端子,電源與通(tong)訊接(jie)線(xian)(xian)采(cai)用(yong)兩(liang)進(jin)(jin)兩(liang)出(chu)接(jie)線(xian)(xian)方式,設有接(jie)線(xian)(xian)端子護(hu)罩,安(an)全又可靠。是具有全數(shu)字傳輸(shu)功能的新一代(dai)高精度雙(shuang)氣(qi)體(ti)檢測(ce)檢測(ce)器(qi)(qi)。

DX6000H型SF6 在線(xian)(xian)監(jian)測報(bao)(bao)警系統適用(yong)(yong)于配電室、開(kai)關(guan)(guan)站、光伏發電廠、海(hai)上風(feng)電場、10KV、35KV、220KV開(kai)關(guan)(guan)柜、GIS室等場所;設備監(jian)測精度高、范圍廣、功能(neng)全(quan),具有(you)良好(hao)的擴展性 2.1 采(cai)用(yong)(yong)1024*600觸摸屏,全(quan)中(zhong)文菜單操作,界面友好(hao),操作簡(jian)單; 2.2 設備集成三組(zu)485接(jie)口(kou),采(cai)用(yong)(yong)插拔式接(jie)線(xian)(xian)端(duan)子接(jie)線(xian)(xian)簡(jian)單,具有(you)良好(hao)的抗干擾能(neng)力,總線(xian)(xian)通訊,布線(xian)(xian)經(jing)濟,安(an)裝(zhuang)方便(bian); 2.3 三組(zu)DC24V接(jie)口(kou),可選配DC3.3V、DC5V、DC12V電壓輸(shu)出,  2.4 自動故障檢測,并能(neng)用(yong)(yong)中(zhong)文顯示處準(zhun)確的故障部位及類型; 2.5 自動檢索(suo)探測器(qi)地址及狀態,SF6/O2/溫(wen)濕度探測器(qi)在同一系統監(jian)控(kong); 2.6 大(da)容量(liang)儲存芯(xin)片(pian),循環記(ji)錄報(bao)(bao)警信息(xi),大(da)可記(ji)錄50000條; 2.7 RS485上傳接(jie)口(kou),標準(zhun)modbus Rtu通訊協議(yi)。

2.8 關(guan)鍵參數(shu)(shu),加密設(she)定,防止誤操作 2.9 多可(ke)(ke)選配7組繼(ji)電器(qi)(qi),繼(ji)電器(qi)(qi)控(kong)制方式(shi)可(ke)(ke)軟(ruan)件設(she)置 2.10 具有 年-月-日-時(shi)-分-秒設(she)置功(gong)能(neng),并且(qie)帶有每周七天(tian)分別顯示(shi)(shi)功(gong)能(neng) 壁(bi)掛(gua)式(shi)SF6氣體(ti)(ti)(ti)報(bao)(bao)(bao)警主(zhu)(zhu)機(ji)(ji)_SF6氧氣一體(ti)(ti)(ti)式(shi)探測(ce)器(qi)(qi)_SF6泄漏在(zai)線(xian)監(jian)測(ce)報(bao)(bao)(bao)警系統_SF6氣體(ti)(ti)(ti)在(zai)線(xian)監(jian)測(ce)報(bao)(bao)(bao)警裝置_SF6氣體(ti)(ti)(ti)在(zai)線(xian)監(jian)測(ce)報(bao)(bao)(bao)警系統 三章:主(zhu)(zhu)要技(ji)術指(zhi)標(biao) 3.1 壁(bi)掛(gua)式(shi)主(zhu)(zhu)機(ji)(ji)技(ji)術指(zhi)標(biao)(DX6000H型) 3.1.1 工作電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸出(chu): RS485 modbus_RTU 協(xie)議(yi)輸出(chu) 3.1.3 工作溫度(du): -20℃~+55℃ 3.1.4 工作濕(shi)度(du): ≤93%RH 3.1.5 顯示(shi)(shi)方式(shi): 列表顯示(shi)(shi),每頁顯示(shi)(shi)8組或(huo)10組數(shu)(shu)據(每組包括SF6/02/溫度(du)/濕(shi)度(du)四(si)種數(shu)(shu)據和兩(liang)種數(shu)(shu)據狀態(tai)) 3.1.6 上傳參數(shu)(shu): 默(mo)認ID 1(可(ke)(ke)調(diao)),默(mo)認波特(te)率9600(可(ke)(ke)調(diao)) 3.1.7 人體(ti)(ti)(ti)感(gan)(gan)應:默(mo)認開啟(qi)(qi)感(gan)(gan)應亮屏(ping)功(gong)能(neng) 3.1.8 屏(ping)幕保(bao)護(hu):默(mo)認開啟(qi)(qi)亮屏(ping)5分鐘后自動(dong)(dong)(dong)息屏(ping),人體(ti)(ti)(ti)感(gan)(gan)應或(huo)觸摸可(ke)(ke)亮屏(ping) 3.1.9 排(pai)風功(gong)能(neng):自動(dong)(dong)(dong)排(pai)風,定時(shi)排(pai)風,手動(dong)(dong)(dong)排(pai)風,延時(shi)排(pai)風,手動(dong)(dong)(dong)排(pai)風可(ke)(ke)設(she)置低1s,大12H,自動(dong)(dong)(dong)排(pai)風分為12組,可(ke)(ke)設(she)置開啟(qi)(qi)組數(shu)(shu)、開啟(qi)(qi)日期、開啟(qi)(qi)時(shi)間(jian)及(ji)啟(qi)(qi)動(dong)(dong)(dong)時(shi)間(jian)(啟(qi)(qi)動(dong)(dong)(dong)時(shi)間(jian)可(ke)(ke)更改)功(gong)能(neng) sf6氣體(ti)(ti)(ti)報(bao)(bao)(bao)警裝置_SF6氣體(ti)(ti)(ti)報(bao)(bao)(bao)警器(qi)(qi)_SF6報(bao)(bao)(bao)警裝置_SF6報(bao)(bao)(bao)警主(zhu)(zhu)機(ji)(ji)_SF6報(bao)(bao)(bao)警器(qi)(qi)。

SF6行業安全(quan)法規摘(zhai)錄 ■191條 裝(zhuang)(zhuang)(zhuang)有SF6設(she)備的配電裝(zhuang)(zhuang)(zhuang)置(zhi)(zhi)(zhi)(zhi)(zhi)室(shi)(shi)和SF6氣體(ti)(ti)實驗室(shi)(shi),必(bi)須裝(zhuang)(zhuang)(zhuang)設(she)強力通風(feng)(feng)裝(zhuang)(zhuang)(zhuang)置(zhi)(zhi)(zhi)(zhi)(zhi)。風(feng)(feng)口應(ying)設(she)置(zhi)(zhi)(zhi)(zhi)(zhi)在(zai)室(shi)(shi)內(nei)低部(bu)。■192條 在(zai)室(shi)(shi)內(nei),設(she)備充裝(zhuang)(zhuang)(zhuang)SF6氣體(ti)(ti)時(shi),周圍(wei)環境相對濕(shi)度(du)應(ying)≤80%,同時(shi)必(bi)須開啟通風(feng)(feng)系統,并避免SF6氣體(ti)(ti)漏(lou)泄到工(gong)作(zuo)區(qu)。工(gong)作(zuo)區(qu)空氣中SF6氣體(ti)(ti)含(han)量(liang)(liang)不(bu)得超過1000ppm。■196條 工(gong)作(zuo)人(ren)員進(jin)入SF6配電裝(zhuang)(zhuang)(zhuang)置(zhi)(zhi)(zhi)(zhi)(zhi)室(shi)(shi),必(bi)須先通風(feng)(feng)15min,并用檢(jian)漏(lou)儀測(ce)量(liang)(liang)SF6氣體(ti)(ti)含(han)量(liang)(liang)。盡(jin)量(liang)(liang)避免一(yi)人(ren)進(jin)入SF6配電裝(zhuang)(zhuang)(zhuang)置(zhi)(zhi)(zhi)(zhi)(zhi)室(shi)(shi)進(jin)行巡視,不(bu)準一(yi)人(ren)進(jin)入從事檢(jian)修工(gong)作(zuo)。■198條 進(jin)入SF6配電裝(zhuang)(zhuang)(zhuang)置(zhi)(zhi)(zhi)(zhi)(zhi)室(shi)(shi)低位區(qu)或(huo)電纜溝進(jin)行工(gong)作(zuo)應(ying)先檢(jian)測(ce)含(han)氧(yang)量(liang)(liang)(不(bu)低于18%)和SF6氣體(ti)(ti)含(han)量(liang)(liang)是(shi)否合格

變電站sf6氣體檢測儀報警裝置多少錢 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 變電站sf6氣體檢測儀報警裝置多少錢

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地址:濟南市高新技術開發區花園路東(dong)首(shou)

電話(hua):15376190119

郵箱:sddx0001@163.com