光伏站sf6在線報警系統探測主機批發SF6檢測報警裝置

發布時間:2023-10-20 21:28:50       發布人:147小編  瀏覽量:

光伏站sf6在線報警系統探測主機批發SF6檢測報警裝置

本系統(tong)采用間歇(xie)式(shi)檢測(ce)(ce)模式(shi),進(jin)行在(zai)線監(jian)(jian)測(ce)(ce)其場所(suo)內SF6氣體濃度(du)(du)(du)及(ji)O2含量和環(huan)境(jing)溫度(du)(du)(du)、濕(shi)度(du)(du)(du)的(de)狀(zhuang)(zhuang)態(tai)監(jian)(jian)測(ce)(ce),當(dang)場所(suo)內SF6濃度(du)(du)(du)及(ji)O2含量和環(huan)境(jing)濕(shi)度(du)(du)(du)發生變化(hua)時(shi),傳感器立即響應這些變化(hua)。實現對(dui)(dui)場所(suo)內SF6濃度(du)(du)(du)及(ji)O2的(de)含量和環(huan)境(jing)溫度(du)(du)(du)、濕(shi)度(du)(du)(du)進(jin)行有效地(di)監(jian)(jian)測(ce)(ce)。通(tong)(tong)過(guo)現場總(zong)線(RS485)由(you)監(jian)(jian)控(kong)報警(jing)主機(ji)采集狀(zhuang)(zhuang)態(tai)參(can)數,當(dang)場所(suo)內出現超限值(zhi)時(shi),進(jin)入預(yu)警(jing)聲(sheng)光報警(jing)同時(shi)啟(qi)(qi)動(dong)風機(ji)進(jin)行通(tong)(tong)風換氣或啟(qi)(qi)動(dong)除濕(shi)機(ji)進(jin)行除濕(shi)。同時(shi)將狀(zhuang)(zhuang)態(tai)參(can)數上傳輸給監(jian)(jian)控(kong)中(zhong)心。在(zai)監(jian)(jian)控(kong)中(zhong)心電子(zi)地(di)圖上進(jin)行定(ding)位及(ji)管理和環(huan)境(jing)參(can)量超過(guo)預(yu)設(she)值(zhi)時(shi)發出視聽(ting)告警(jing)在(zai)電子(zi)地(di)圖界面上閃爍顯(xian)示,按(an)照(zhao)預(yu)設(she)置聯動(dong)方(fang)案,對(dui)(dui)通(tong)(tong)道門(men)體、風機(ji)以(yi)及(ji)水泵(beng)等進(jin)行管理;以(yi)及(ji)通(tong)(tong)過(guo)語音、短信方(fang)式(shi)自動(dong)通(tong)(tong)知值(zhi)班維護人員

顯(xian)(xian)示(shi)屏由(you)控(kong)制單(dan)(dan)(dan)元(yuan)(yuan)、通信單(dan)(dan)(dan)元(yuan)(yuan)、人(ren)體感(gan)應啟(qi)動(dong)顯(xian)(xian)示(shi)及(ji)(ji)語音播(bo)(bo)報單(dan)(dan)(dan)元(yuan)(yuan)組(zu)成,當人(ren)體感(gan)應器感(gan)應到人(ren)身啟(qi)動(dong)信息,將啟(qi)動(dong)信息通過485總線傳輸(shu)給監控(kong)主機(ji),由(you)監控(kong)主機(ji)控(kong)制顯(xian)(xian)示(shi)單(dan)(dan)(dan)元(yuan)(yuan)顯(xian)(xian)示(shi)室內SF6高值(zhi)及(ji)(ji)對應機(ji)號和O2低值(zhi)及(ji)(ji)對應機(ji)號,后顯(xian)(xian)示(shi)室內是否安(an)(an)全,同(tong)時語音播(bo)(bo)報顯(xian)(xian)示(shi)內容(rong)。專為多個(ge)入口而設計,一般安(an)(an)裝在場(chang)所(suo)入口處,為工(gong)作人(ren)員(yuan)在進入每個(ge)入口時都(dou)能及(ji)(ji)時播(bo)(bo)報和顯(xian)(xian)示(shi)場(chang)所(suo)內狀態和安(an)(an)全情(qing)況(kuang)。

DX6000H型SF6 在線(xian)監測(ce)(ce)報(bao)(bao)警系統適用(yong)于配電室、開(kai)關(guan)站、光(guang)伏發電廠、海上(shang)風電場、10KV、35KV、220KV開(kai)關(guan)柜、GIS室等場所;設備監測(ce)(ce)精度高、范圍廣、功能全(quan),具有良(liang)好(hao)的擴展(zhan)性(xing) 2.1 采用(yong)1024*600觸摸屏,全(quan)中文(wen)菜(cai)單操作(zuo)(zuo),界面友好(hao),操作(zuo)(zuo)簡單; 2.2 設備集(ji)成三(san)組(zu)(zu)485接(jie)口(kou)(kou),采用(yong)插(cha)拔式接(jie)線(xian)端(duan)子接(jie)線(xian)簡單,具有良(liang)好(hao)的抗干擾(rao)能力,總線(xian)通(tong)訊,布線(xian)經濟,安裝(zhuang)方便(bian); 2.3 三(san)組(zu)(zu)DC24V接(jie)口(kou)(kou),可(ke)選配DC3.3V、DC5V、DC12V電壓輸出(chu), 2.4 自動故障檢測(ce)(ce),并能用(yong)中文(wen)顯示處準確的故障部位(wei)及類型; 2.5 自動檢索探(tan)測(ce)(ce)器(qi)地址(zhi)及狀態,SF6/O2/溫(wen)濕度探(tan)測(ce)(ce)器(qi)在同一系統監控; 2.6 大(da)容量儲(chu)存芯片(pian),循環記(ji)錄報(bao)(bao)警信息,大(da)可(ke)記(ji)錄50000條; 2.7 RS485上(shang)傳接(jie)口(kou)(kou),標(biao)準modbus Rtu通(tong)訊協議(yi)。

2.8 關(guan)鍵參數(shu)(shu)(shu),加(jia)密(mi)設(she)定(ding),防止誤操作 2.9 多可(ke)(ke)(ke)(ke)(ke)選配7組(zu)繼電(dian)器(qi),繼電(dian)器(qi)控制方式(shi)可(ke)(ke)(ke)(ke)(ke)軟件設(she)置(zhi) 2.10 具有 年-月-日-時(shi)(shi)-分(fen)-秒設(she)置(zhi)功(gong)(gong)(gong)(gong)能(neng)(neng),并且帶有每(mei)(mei)周七天分(fen)別(bie)顯(xian)示(shi)(shi)功(gong)(gong)(gong)(gong)能(neng)(neng) 壁掛(gua)式(shi)SF6氣(qi)(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)(jing)主(zhu)機(ji)_SF6氧氣(qi)(qi)(qi)一體(ti)(ti)(ti)式(shi)探測器(qi)_SF6泄漏在(zai)線(xian)監(jian)測報(bao)(bao)警(jing)(jing)(jing)系(xi)(xi)統_SF6氣(qi)(qi)(qi)體(ti)(ti)(ti)在(zai)線(xian)監(jian)測報(bao)(bao)警(jing)(jing)(jing)裝置(zhi)_SF6氣(qi)(qi)(qi)體(ti)(ti)(ti)在(zai)線(xian)監(jian)測報(bao)(bao)警(jing)(jing)(jing)系(xi)(xi)統 三章:主(zhu)要技術指標 3.1 壁掛(gua)式(shi)主(zhu)機(ji)技術指標(DX6000H型) 3.1.1 工作電(dian)壓(ya): AC220V±15%,50Hz±1% 3.1.2 信號(hao)輸(shu)出: RS485 modbus_RTU 協(xie)議輸(shu)出 3.1.3 工作溫(wen)度: -20℃~+55℃ 3.1.4 工作濕度: ≤93%RH 3.1.5 顯(xian)示(shi)(shi)方式(shi): 列表顯(xian)示(shi)(shi),每(mei)(mei)頁(ye)顯(xian)示(shi)(shi)8組(zu)或10組(zu)數(shu)(shu)(shu)據(ju)(每(mei)(mei)組(zu)包括SF6/02/溫(wen)度/濕度四種數(shu)(shu)(shu)據(ju)和兩種數(shu)(shu)(shu)據(ju)狀(zhuang)態(tai)) 3.1.6 上(shang)傳參數(shu)(shu)(shu): 默(mo)認(ren)ID 1(可(ke)(ke)(ke)(ke)(ke)調),默(mo)認(ren)波特率9600(可(ke)(ke)(ke)(ke)(ke)調) 3.1.7 人體(ti)(ti)(ti)感應:默(mo)認(ren)開啟(qi)感應亮屏(ping)功(gong)(gong)(gong)(gong)能(neng)(neng) 3.1.8 屏(ping)幕保護:默(mo)認(ren)開啟(qi)亮屏(ping)5分(fen)鐘后自(zi)動(dong)息屏(ping),人體(ti)(ti)(ti)感應或觸摸(mo)可(ke)(ke)(ke)(ke)(ke)亮屏(ping) 3.1.9 排風功(gong)(gong)(gong)(gong)能(neng)(neng):自(zi)動(dong)排風,定(ding)時(shi)(shi)排風,手動(dong)排風,延時(shi)(shi)排風,手動(dong)排風可(ke)(ke)(ke)(ke)(ke)設(she)置(zhi)低1s,大12H,自(zi)動(dong)排風分(fen)為12組(zu),可(ke)(ke)(ke)(ke)(ke)設(she)置(zhi)開啟(qi)組(zu)數(shu)(shu)(shu)、開啟(qi)日期、開啟(qi)時(shi)(shi)間(jian)及啟(qi)動(dong)時(shi)(shi)間(jian)(啟(qi)動(dong)時(shi)(shi)間(jian)可(ke)(ke)(ke)(ke)(ke)更(geng)改)功(gong)(gong)(gong)(gong)能(neng)(neng) sf6氣(qi)(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)(jing)裝置(zhi)_SF6氣(qi)(qi)(qi)體(ti)(ti)(ti)報(bao)(bao)警(jing)(jing)(jing)器(qi)_SF6報(bao)(bao)警(jing)(jing)(jing)裝置(zhi)_SF6報(bao)(bao)警(jing)(jing)(jing)主(zhu)機(ji)_SF6報(bao)(bao)警(jing)(jing)(jing)器(qi)。

SF6行業安全法規摘錄 ■191條(tiao) 裝(zhuang)(zhuang)(zhuang)有SF6設(she)備(bei)的配(pei)電裝(zhuang)(zhuang)(zhuang)置室(shi)(shi)(shi)和SF6氣(qi)體(ti)實驗(yan)室(shi)(shi)(shi),必須裝(zhuang)(zhuang)(zhuang)設(she)強力通風(feng)(feng)裝(zhuang)(zhuang)(zhuang)置。風(feng)(feng)口(kou)應(ying)設(she)置在室(shi)(shi)(shi)內低部。■192條(tiao) 在室(shi)(shi)(shi)內,設(she)備(bei)充裝(zhuang)(zhuang)(zhuang)SF6氣(qi)體(ti)時(shi),周圍環境相對濕(shi)度應(ying)≤80%,同時(shi)必須開(kai)啟通風(feng)(feng)系(xi)統,并避免(mian)SF6氣(qi)體(ti)漏泄(xie)到(dao)工(gong)(gong)作(zuo)(zuo)(zuo)區(qu)(qu)。工(gong)(gong)作(zuo)(zuo)(zuo)區(qu)(qu)空氣(qi)中SF6氣(qi)體(ti)含(han)量(liang)(liang)不(bu)得超過1000ppm。■196條(tiao) 工(gong)(gong)作(zuo)(zuo)(zuo)人員進(jin)(jin)(jin)入SF6配(pei)電裝(zhuang)(zhuang)(zhuang)置室(shi)(shi)(shi),必須先(xian)通風(feng)(feng)15min,并用(yong)檢漏儀測(ce)量(liang)(liang)SF6氣(qi)體(ti)含(han)量(liang)(liang)。盡(jin)量(liang)(liang)避免(mian)一人進(jin)(jin)(jin)入SF6配(pei)電裝(zhuang)(zhuang)(zhuang)置室(shi)(shi)(shi)進(jin)(jin)(jin)行巡視,不(bu)準一人進(jin)(jin)(jin)入從事檢修工(gong)(gong)作(zuo)(zuo)(zuo)。■198條(tiao) 進(jin)(jin)(jin)入SF6配(pei)電裝(zhuang)(zhuang)(zhuang)置室(shi)(shi)(shi)低位區(qu)(qu)或電纜溝(gou)進(jin)(jin)(jin)行工(gong)(gong)作(zuo)(zuo)(zuo)應(ying)先(xian)檢測(ce)含(han)氧量(liang)(liang)(不(bu)低于18%)和SF6氣(qi)體(ti)含(han)量(liang)(liang)是否合格