核電站sf6氣體泄漏報警監測報警主機多少錢

本系(xi)統(tong)采用間歇式檢(jian)測模式,進(jin)(jin)行(xing)在線(xian)監(jian)測其場所(suo)內(nei)SF6氣體濃度(du)(du)(du)及(ji)(ji)(ji)O2含(han)(han)量(liang)和(he)環(huan)(huan)境溫(wen)度(du)(du)(du)、濕(shi)度(du)(du)(du)的(de)狀(zhuang)(zhuang)態(tai)監(jian)測,當場所(suo)內(nei)SF6濃度(du)(du)(du)及(ji)(ji)(ji)O2含(han)(han)量(liang)和(he)環(huan)(huan)境濕(shi)度(du)(du)(du)發生變化(hua)時(shi),傳感(gan)器立即響應(ying)這些變化(hua)。實現對(dui)場所(suo)內(nei)SF6濃度(du)(du)(du)及(ji)(ji)(ji)O2的(de)含(han)(han)量(liang)和(he)環(huan)(huan)境溫(wen)度(du)(du)(du)、濕(shi)度(du)(du)(du)進(jin)(jin)行(xing)有效地監(jian)測。通(tong)(tong)過現場總線(xian)(RS485)由監(jian)控(kong)報(bao)警主機采集狀(zhuang)(zhuang)態(tai)參(can)(can)數,當場所(suo)內(nei)出現超(chao)限(xian)值(zhi)時(shi),進(jin)(jin)入預(yu)(yu)警聲光報(bao)警同時(shi)啟動(dong)(dong)風機進(jin)(jin)行(xing)通(tong)(tong)風換氣或啟動(dong)(dong)除(chu)濕(shi)機進(jin)(jin)行(xing)除(chu)濕(shi)。同時(shi)將狀(zhuang)(zhuang)態(tai)參(can)(can)數上傳輸給(gei)監(jian)控(kong)中心(xin)。在監(jian)控(kong)中心(xin)電(dian)子(zi)地圖(tu)上進(jin)(jin)行(xing)定位及(ji)(ji)(ji)管理(li)和(he)環(huan)(huan)境參(can)(can)量(liang)超(chao)過預(yu)(yu)設值(zhi)時(shi)發出視聽告警在電(dian)子(zi)地圖(tu)界面上閃爍顯示(shi),按(an)照預(yu)(yu)設置聯動(dong)(dong)方(fang)案,對(dui)通(tong)(tong)道門體、風機以及(ji)(ji)(ji)水泵等進(jin)(jin)行(xing)管理(li);以及(ji)(ji)(ji)通(tong)(tong)過語音、短信方(fang)式自動(dong)(dong)通(tong)(tong)知(zhi)值(zhi)班維護人員(yuan)

雙氣體(ti)檢(jian)測器(qi)(qi)主要由傳感(gan)器(qi)(qi)、單(dan)片機(ji)、運算放(fang)大(da)電(dian)路、通(tong)(tong)訊芯(xin)片等組成。傳感(gan)器(qi)(qi)將(jiang)氣體(ti)濃(nong)度轉(zhuan)(zhuan)換為模擬電(dian)信(xin)(xin)號(hao),然后將(jiang)模擬電(dian)信(xin)(xin)號(hao)通(tong)(tong)過運算放(fang)大(da)電(dian)路、單(dan)片機(ji)轉(zhuan)(zhuan)換為數字信(xin)(xin)號(hao),后通(tong)(tong)過通(tong)(tong)訊芯(xin)片轉(zhuan)(zhuan)換為modbus RTU標準信(xin)(xin)號(hao),上傳給控制器(qi)(qi)。

DX6000H型SF6 在(zai)線(xian)(xian)監測(ce)(ce)(ce)報警系統適用于配電(dian)室、開(kai)(kai)關站、光伏發電(dian)廠、海上風電(dian)場、10KV、35KV、220KV開(kai)(kai)關柜、GIS室等(deng)場所;設備(bei)監測(ce)(ce)(ce)精度(du)高、范(fan)圍(wei)廣、功(gong)能全(quan),具(ju)有良(liang)好的(de)擴(kuo)展性 2.1 采用1024*600觸(chu)摸屏,全(quan)中(zhong)(zhong)文菜單(dan)操作,界面友好,操作簡單(dan);  2.2 設備(bei)集成三組485接口,采用插拔(ba)式接線(xian)(xian)端子(zi)接線(xian)(xian)簡單(dan),具(ju)有良(liang)好的(de)抗干擾能力(li),總線(xian)(xian)通(tong)訊,布線(xian)(xian)經濟(ji),安(an)裝(zhuang)方便(bian); 2.3 三組DC24V接口,可選配DC3.3V、DC5V、DC12V電(dian)壓輸出, 2.4 自動故(gu)障檢測(ce)(ce)(ce),并能用中(zhong)(zhong)文顯示處準(zhun)確的(de)故(gu)障部位及類型; 2.5 自動檢索探測(ce)(ce)(ce)器地址(zhi)及狀態,SF6/O2/溫濕度(du)探測(ce)(ce)(ce)器在(zai)同一(yi)系統監控(kong); 2.6 大容(rong)量儲存芯片,循(xun)環記錄報警信息,大可記錄50000條(tiao); 2.7 RS485上傳(chuan)接口,標準(zhun)modbus Rtu通(tong)訊協議。

2.8 關鍵參(can)數,加密設(she)定,防止誤操作(zuo) 2.9 多可(ke)(ke)(ke)選配7組(zu)繼(ji)電(dian)器,繼(ji)電(dian)器控制方(fang)式(shi)可(ke)(ke)(ke)軟件設(she)置(zhi)(zhi)(zhi) 2.10 具有 年-月(yue)-日-時(shi)(shi)-分(fen)-秒設(she)置(zhi)(zhi)(zhi)功(gong)能,并且帶有每周七(qi)天分(fen)別顯(xian)示(shi)功(gong)能 壁掛(gua)式(shi)SF6氣(qi)(qi)體報(bao)警(jing)(jing)(jing)(jing)主(zhu)機_SF6氧氣(qi)(qi)一(yi)體式(shi)探(tan)測(ce)器_SF6泄漏在線(xian)(xian)(xian)監測(ce)報(bao)警(jing)(jing)(jing)(jing)系(xi)統_SF6氣(qi)(qi)體在線(xian)(xian)(xian)監測(ce)報(bao)警(jing)(jing)(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6氣(qi)(qi)體在線(xian)(xian)(xian)監測(ce)報(bao)警(jing)(jing)(jing)(jing)系(xi)統 三章:主(zhu)要技術(shu)指(zhi)標 3.1 壁掛(gua)式(shi)主(zhu)機技術(shu)指(zhi)標(DX6000H型(xing)) 3.1.1 工(gong)(gong)作(zuo)電(dian)壓: AC220V±15%,50Hz±1% 3.1.2 信(xin)號輸(shu)出: RS485 modbus_RTU 協議輸(shu)出 3.1.3 工(gong)(gong)作(zuo)溫度: -20℃~+55℃ 3.1.4 工(gong)(gong)作(zuo)濕度: ≤93%RH 3.1.5 顯(xian)示(shi)方(fang)式(shi): 列表顯(xian)示(shi),每頁顯(xian)示(shi)8組(zu)或(huo)10組(zu)數據(ju)(每組(zu)包(bao)括SF6/02/溫度/濕度四種數據(ju)和(he)兩(liang)種數據(ju)狀態) 3.1.6 上傳(chuan)參(can)數: 默認(ren)ID 1(可(ke)(ke)(ke)調(diao)),默認(ren)波特率9600(可(ke)(ke)(ke)調(diao)) 3.1.7 人(ren)體感應:默認(ren)開(kai)啟(qi)(qi)感應亮屏功(gong)能 3.1.8 屏幕保護:默認(ren)開(kai)啟(qi)(qi)亮屏5分(fen)鐘(zhong)后自(zi)動(dong)息屏,人(ren)體感應或(huo)觸(chu)摸可(ke)(ke)(ke)亮屏 3.1.9 排(pai)(pai)(pai)風(feng)功(gong)能:自(zi)動(dong)排(pai)(pai)(pai)風(feng),定時(shi)(shi)排(pai)(pai)(pai)風(feng),手(shou)動(dong)排(pai)(pai)(pai)風(feng),延(yan)時(shi)(shi)排(pai)(pai)(pai)風(feng),手(shou)動(dong)排(pai)(pai)(pai)風(feng)可(ke)(ke)(ke)設(she)置(zhi)(zhi)(zhi)低(di)1s,大12H,自(zi)動(dong)排(pai)(pai)(pai)風(feng)分(fen)為12組(zu),可(ke)(ke)(ke)設(she)置(zhi)(zhi)(zhi)開(kai)啟(qi)(qi)組(zu)數、開(kai)啟(qi)(qi)日期、開(kai)啟(qi)(qi)時(shi)(shi)間(jian)及(ji)啟(qi)(qi)動(dong)時(shi)(shi)間(jian)(啟(qi)(qi)動(dong)時(shi)(shi)間(jian)可(ke)(ke)(ke)更改(gai))功(gong)能 sf6氣(qi)(qi)體報(bao)警(jing)(jing)(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6氣(qi)(qi)體報(bao)警(jing)(jing)(jing)(jing)器_SF6報(bao)警(jing)(jing)(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6報(bao)警(jing)(jing)(jing)(jing)主(zhu)機_SF6報(bao)警(jing)(jing)(jing)(jing)器。

SF6行業安全(quan)法規摘錄 ■191條 裝(zhuang)有SF6設備的配(pei)(pei)電(dian)裝(zhuang)置(zhi)室(shi)和(he)(he)SF6氣(qi)(qi)體(ti)(ti)(ti)實驗(yan)室(shi),必須裝(zhuang)設強力通(tong)風裝(zhuang)置(zhi)。風口應(ying)設置(zhi)在(zai)室(shi)內低(di)部。■192條 在(zai)室(shi)內,設備充裝(zhuang)SF6氣(qi)(qi)體(ti)(ti)(ti)時,周圍環境相對濕度應(ying)≤80%,同時必須開啟通(tong)風系統(tong),并避免SF6氣(qi)(qi)體(ti)(ti)(ti)漏泄到工(gong)(gong)作(zuo)區(qu)。工(gong)(gong)作(zuo)區(qu)空氣(qi)(qi)中SF6氣(qi)(qi)體(ti)(ti)(ti)含量不(bu)(bu)得超過1000ppm。■196條 工(gong)(gong)作(zuo)人(ren)(ren)員進(jin)入SF6配(pei)(pei)電(dian)裝(zhuang)置(zhi)室(shi),必須先通(tong)風15min,并用檢漏儀測量SF6氣(qi)(qi)體(ti)(ti)(ti)含量。盡量避免一人(ren)(ren)進(jin)入SF6配(pei)(pei)電(dian)裝(zhuang)置(zhi)室(shi)進(jin)行巡視,不(bu)(bu)準一人(ren)(ren)進(jin)入從事檢修工(gong)(gong)作(zuo)。■198條 進(jin)入SF6配(pei)(pei)電(dian)裝(zhuang)置(zhi)室(shi)低(di)位(wei)區(qu)或電(dian)纜溝進(jin)行工(gong)(gong)作(zuo)應(ying)先檢測含氧量(不(bu)(bu)低(di)于18%)和(he)(he)SF6氣(qi)(qi)體(ti)(ti)(ti)含量是(shi)否(fou)合格