久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱線電話:15376190119
您所在的位置: 主頁 ? 新聞動態 ? 公司新聞

光伏站sf6環境監測報警系統監控主機多少錢

發布時間:2023-11-28 01:49:07       發布人:dxdz  瀏覽量:

光伏站sf6環境監測報警系統監控主機多少錢

SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)泄(xie)漏監控子(zi)系(xi)統主要對SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)為絕緣介質的(de)高壓電(dian)(dian)器設備(bei)(bei)場所內(nei)進(jin)(jin)行(xing)環境監測(ce)。當(dang)場所內(nei)設備(bei)(bei)發生SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)泄(xie)漏時,由于(yu)SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)的(de)密度(du)是(shi)空氣(qi)(qi)(qi)(qi)的(de)5倍,積累于(yu)底層空間,并造成局部(bu)(bu)缺氧,引起嚴重(zhong)事(shi)故。為此:《電(dian)(dian)業(ye)安(an)全工(gong)作(zuo)規程》(發電(dian)(dian)廠和變電(dian)(dian)站部(bu)(bu)分)特別規定,工(gong)作(zuo)人員(yuan)進(jin)(jin)入SF6配電(dian)(dian)裝置室低(di)位(wei)區(qu)或電(dian)(dian)纜溝進(jin)(jin)行(xing)工(gong)作(zuo)必(bi)須(xu)保證SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)濃度(du)小(xiao)于(yu)1000ppm,含氧量不低(di)于(yu)18%及周圍(wei)環境相對濕度(du)80%,同時必(bi)須(xu)開啟通風系(xi)統。SF6+O2雙(shuang)氣(qi)(qi)(qi)(qi)體(ti)(ti)探(tan)測(ce)器_SF6+O2氣(qi)(qi)(qi)(qi)體(ti)(ti)探(tan)測(ce)器_SF6+O2探(tan)測(ce)器_SF6+O2雙(shuang)氣(qi)(qi)(qi)(qi)體(ti)(ti)探(tan)頭(tou)_SF6+O2氣(qi)(qi)(qi)(qi)體(ti)(ti)探(tan)頭(tou)_sf6氣(qi)(qi)(qi)(qi)體(ti)(ti)檢(jian)測(ce)儀

雙氣體(ti)檢測器(qi)(qi)主(zhu)要由傳感器(qi)(qi)、單片機、運(yun)算放大電(dian)(dian)路(lu)、通(tong)訊(xun)芯(xin)片等組(zu)成。傳感器(qi)(qi)將(jiang)氣體(ti)濃度轉換為(wei)模(mo)擬(ni)電(dian)(dian)信(xin)號,然后(hou)將(jiang)模(mo)擬(ni)電(dian)(dian)信(xin)號通(tong)過(guo)運(yun)算放大電(dian)(dian)路(lu)、單片機轉換為(wei)數字信(xin)號,后(hou)通(tong)過(guo)通(tong)訊(xun)芯(xin)片轉換為(wei)modbus RTU標準信(xin)號,上傳給控制器(qi)(qi)。

DX6000H型(xing)(xing)SF6 在(zai)線(xian)(xian)監(jian)測(ce)(ce)報警(jing)系統(tong)適用(yong)(yong)于配電(dian)(dian)室、開關站、光伏發電(dian)(dian)廠、海(hai)上風電(dian)(dian)場(chang)、10KV、35KV、220KV開關柜、GIS室等場(chang)所;設備監(jian)測(ce)(ce)精度高(gao)、范圍(wei)廣、功能(neng)全,具有(you)良好(hao)的(de)擴展性 2.1 采用(yong)(yong)1024*600觸(chu)摸屏,全中文(wen)菜單(dan)操作(zuo),界面(mian)友好(hao),操作(zuo)簡單(dan); 2.2 設備集成三(san)組485接口,采用(yong)(yong)插拔式接線(xian)(xian)端子接線(xian)(xian)簡單(dan),具有(you)良好(hao)的(de)抗干擾能(neng)力,總線(xian)(xian)通訊,布線(xian)(xian)經濟,安(an)裝(zhuang)方便(bian); 2.3 三(san)組DC24V接口,可選配DC3.3V、DC5V、DC12V電(dian)(dian)壓輸(shu)出, 2.4 自動故障檢(jian)測(ce)(ce),并能(neng)用(yong)(yong)中文(wen)顯(xian)示(shi)處準確的(de)故障部(bu)位及類(lei)型(xing)(xing); 2.5 自動檢(jian)索探(tan)測(ce)(ce)器(qi)地址及狀態(tai),SF6/O2/溫濕度探(tan)測(ce)(ce)器(qi)在(zai)同(tong)一系統(tong)監(jian)控(kong); 2.6 大容量儲存芯(xin)片,循環記錄報警(jing)信息,大可記錄50000條; 2.7 RS485上傳(chuan)接口,標準modbus Rtu通訊協議。

2.8 關鍵參數,加密設(she)定(ding),防止誤操作 2.9 多可(ke)(ke)(ke)(ke)選配7組(zu)繼(ji)電器,繼(ji)電器控制方式(shi)(shi)可(ke)(ke)(ke)(ke)軟(ruan)件(jian)設(she)置(zhi)(zhi)(zhi) 2.10 具有 年-月(yue)-日-時(shi)(shi)(shi)(shi)(shi)-分-秒設(she)置(zhi)(zhi)(zhi)功(gong)(gong)(gong)能(neng),并且帶有每周(zhou)七天(tian)分別顯示(shi)功(gong)(gong)(gong)能(neng) 壁掛式(shi)(shi)SF6氣(qi)體(ti)(ti)報警主(zhu)機_SF6氧氣(qi)一體(ti)(ti)式(shi)(shi)探測器_SF6泄漏在線監(jian)(jian)測報警系統_SF6氣(qi)體(ti)(ti)在線監(jian)(jian)測報警裝置(zhi)(zhi)(zhi)_SF6氣(qi)體(ti)(ti)在線監(jian)(jian)測報警系統 三章(zhang):主(zhu)要技術指標 3.1 壁掛式(shi)(shi)主(zhu)機技術指標(DX6000H型(xing)) 3.1.1 工(gong)作電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸出(chu): RS485 modbus_RTU 協議輸出(chu) 3.1.3 工(gong)作溫度(du): -20℃~+55℃ 3.1.4 工(gong)作濕度(du): ≤93%RH 3.1.5 顯示(shi)方式(shi)(shi): 列表顯示(shi),每頁(ye)顯示(shi)8組(zu)或(huo)10組(zu)數據(ju)(每組(zu)包括(kuo)SF6/02/溫度(du)/濕度(du)四種(zhong)數據(ju)和(he)兩種(zhong)數據(ju)狀(zhuang)態(tai)) 3.1.6 上傳參數: 默認ID 1(可(ke)(ke)(ke)(ke)調(diao)),默認波特(te)率9600(可(ke)(ke)(ke)(ke)調(diao)) 3.1.7 人體(ti)(ti)感(gan)應:默認開(kai)(kai)啟(qi)感(gan)應亮(liang)屏功(gong)(gong)(gong)能(neng) 3.1.8 屏幕保護:默認開(kai)(kai)啟(qi)亮(liang)屏5分鐘后(hou)自(zi)動(dong)(dong)(dong)息屏,人體(ti)(ti)感(gan)應或(huo)觸摸(mo)可(ke)(ke)(ke)(ke)亮(liang)屏 3.1.9 排風(feng)功(gong)(gong)(gong)能(neng):自(zi)動(dong)(dong)(dong)排風(feng),定(ding)時(shi)(shi)(shi)(shi)(shi)排風(feng),手動(dong)(dong)(dong)排風(feng),延時(shi)(shi)(shi)(shi)(shi)排風(feng),手動(dong)(dong)(dong)排風(feng)可(ke)(ke)(ke)(ke)設(she)置(zhi)(zhi)(zhi)低1s,大12H,自(zi)動(dong)(dong)(dong)排風(feng)分為12組(zu),可(ke)(ke)(ke)(ke)設(she)置(zhi)(zhi)(zhi)開(kai)(kai)啟(qi)組(zu)數、開(kai)(kai)啟(qi)日期、開(kai)(kai)啟(qi)時(shi)(shi)(shi)(shi)(shi)間及啟(qi)動(dong)(dong)(dong)時(shi)(shi)(shi)(shi)(shi)間(啟(qi)動(dong)(dong)(dong)時(shi)(shi)(shi)(shi)(shi)間可(ke)(ke)(ke)(ke)更(geng)改)功(gong)(gong)(gong)能(neng) sf6氣(qi)體(ti)(ti)報警裝置(zhi)(zhi)(zhi)_SF6氣(qi)體(ti)(ti)報警器_SF6報警裝置(zhi)(zhi)(zhi)_SF6報警主(zhu)機_SF6報警器。

SF6行業(ye)安全(quan)法規摘錄 ■191條(tiao) 裝(zhuang)(zhuang)有SF6設(she)(she)備的配(pei)(pei)(pei)電裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)(shi)(shi)和SF6氣(qi)(qi)體(ti)實驗室(shi)(shi)(shi),必須裝(zhuang)(zhuang)設(she)(she)強力(li)通風(feng)裝(zhuang)(zhuang)置(zhi)(zhi)。風(feng)口應(ying)(ying)設(she)(she)置(zhi)(zhi)在(zai)室(shi)(shi)(shi)內低(di)部(bu)。■192條(tiao) 在(zai)室(shi)(shi)(shi)內,設(she)(she)備充裝(zhuang)(zhuang)SF6氣(qi)(qi)體(ti)時,周(zhou)圍環境相對濕度應(ying)(ying)≤80%,同時必須開啟通風(feng)系(xi)統,并(bing)避(bi)免(mian)SF6氣(qi)(qi)體(ti)漏泄到工(gong)(gong)作(zuo)(zuo)區(qu)(qu)。工(gong)(gong)作(zuo)(zuo)區(qu)(qu)空氣(qi)(qi)中(zhong)SF6氣(qi)(qi)體(ti)含(han)量不得(de)超(chao)過1000ppm。■196條(tiao) 工(gong)(gong)作(zuo)(zuo)人(ren)(ren)員進(jin)入SF6配(pei)(pei)(pei)電裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)(shi)(shi),必須先(xian)通風(feng)15min,并(bing)用檢(jian)漏儀測量SF6氣(qi)(qi)體(ti)含(han)量。盡量避(bi)免(mian)一人(ren)(ren)進(jin)入SF6配(pei)(pei)(pei)電裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)(shi)(shi)進(jin)行巡視,不準(zhun)一人(ren)(ren)進(jin)入從事檢(jian)修(xiu)工(gong)(gong)作(zuo)(zuo)。■198條(tiao) 進(jin)入SF6配(pei)(pei)(pei)電裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)(shi)(shi)低(di)位區(qu)(qu)或(huo)電纜溝進(jin)行工(gong)(gong)作(zuo)(zuo)應(ying)(ying)先(xian)檢(jian)測含(han)氧(yang)量(不低(di)于18%)和SF6氣(qi)(qi)體(ti)含(han)量是(shi)否合格(ge)

光伏站sf6環境監測報警系統監控主機多少錢 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6環境監測報警系統監控主機多少錢

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地(di)址(zhi):濟南市高新(xin)技(ji)術(shu)開發(fa)區花園路東首

電話:15376190119

郵箱:sddx0001@163.com