久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱線(xian)電(dian)話:15376190119
您所在的位置: 主頁 ? 新聞動態 ? 常見問題解答

高壓配電柜sf6濃度監測系統監控主機多少錢

發布時間:2024-02-18 02:29:15       發布人:dxdz  瀏覽量:

高壓配電柜sf6濃度監測系統監控主機多少錢

SF6氣體(ti)(ti)(ti)泄(xie)(xie)漏監(jian)控子(zi)系統(tong)主要對(dui)SF6氣體(ti)(ti)(ti)為絕(jue)緣介(jie)質的高(gao)壓電(dian)(dian)(dian)器設備場所(suo)內(nei)進行(xing)環境監(jian)測(ce)(ce)。當(dang)場所(suo)內(nei)設備發生SF6氣體(ti)(ti)(ti)泄(xie)(xie)漏時,由(you)于(yu)(yu)SF6氣體(ti)(ti)(ti)的密(mi)度是空氣的5倍,積累(lei)于(yu)(yu)底層空間(jian),并造成局部缺氧,引起嚴重事(shi)故。為此:《電(dian)(dian)(dian)業(ye)安全(quan)工(gong)作(zuo)(zuo)規程》(發電(dian)(dian)(dian)廠和(he)變電(dian)(dian)(dian)站部分(fen))特別規定,工(gong)作(zuo)(zuo)人員進入SF6配電(dian)(dian)(dian)裝置室低位區或電(dian)(dian)(dian)纜(lan)溝進行(xing)工(gong)作(zuo)(zuo)必須保證SF6氣體(ti)(ti)(ti)濃度小(xiao)于(yu)(yu)1000ppm,含氧量(liang)不低于(yu)(yu)18%及周圍(wei)環境相對(dui)濕度80%,同時必須開啟通風系統(tong)。SF6+O2雙氣體(ti)(ti)(ti)探(tan)測(ce)(ce)器_SF6+O2氣體(ti)(ti)(ti)探(tan)測(ce)(ce)器_SF6+O2探(tan)測(ce)(ce)器_SF6+O2雙氣體(ti)(ti)(ti)探(tan)頭_SF6+O2氣體(ti)(ti)(ti)探(tan)頭_sf6氣體(ti)(ti)(ti)檢測(ce)(ce)儀

顯(xian)(xian)示屏由控制單元、通信(xin)(xin)單元、人體感應(ying)啟(qi)動(dong)顯(xian)(xian)示及語(yu)音(yin)播報單元組成,當(dang)人體感應(ying)器感應(ying)到人身啟(qi)動(dong)信(xin)(xin)息,將啟(qi)動(dong)信(xin)(xin)息通過485總線傳輸(shu)給監(jian)控主(zhu)機(ji)(ji),由監(jian)控主(zhu)機(ji)(ji)控制顯(xian)(xian)示單元顯(xian)(xian)示室(shi)內(nei)SF6高值(zhi)及對(dui)應(ying)機(ji)(ji)號(hao)和O2低值(zhi)及對(dui)應(ying)機(ji)(ji)號(hao),后顯(xian)(xian)示室(shi)內(nei)是(shi)否(fou)安(an)(an)全,同時語(yu)音(yin)播報顯(xian)(xian)示內(nei)容。專為多個(ge)入(ru)口(kou)而設計,一般安(an)(an)裝在(zai)場(chang)所入(ru)口(kou)處,為工作人員在(zai)進入(ru)每(mei)個(ge)入(ru)口(kou)時都(dou)能及時播報和顯(xian)(xian)示場(chang)所內(nei)狀態和安(an)(an)全情況。

DX6000H型SF6 在線(xian)監測(ce)(ce)(ce)報警(jing)系(xi)統(tong)適(shi)用于配(pei)電室、開(kai)(kai)關站、光伏發電廠、海上風電場(chang)(chang)、10KV、35KV、220KV開(kai)(kai)關柜(ju)、GIS室等場(chang)(chang)所;設備監測(ce)(ce)(ce)精度高、范圍廣(guang)、功能全,具(ju)有良(liang)好的擴展性(xing) 2.1 采用1024*600觸(chu)摸屏(ping),全中(zhong)文菜單(dan)操(cao)作,界面友好,操(cao)作簡(jian)單(dan); 2.2 設備集成三(san)組485接(jie)口(kou)(kou)(kou),采用插拔(ba)式接(jie)線(xian)端(duan)子接(jie)線(xian)簡(jian)單(dan),具(ju)有良(liang)好的抗干擾能力(li),總線(xian)通(tong)訊,布線(xian)經濟,安(an)裝(zhuang)方便(bian); 2.3 三(san)組DC24V接(jie)口(kou)(kou)(kou),可選配(pei)DC3.3V、DC5V、DC12V電壓(ya)輸出, 2.4 自(zi)(zi)動故(gu)(gu)障檢測(ce)(ce)(ce),并能用中(zhong)文顯示處(chu)準確的故(gu)(gu)障部位(wei)及類型; 2.5 自(zi)(zi)動檢索(suo)探測(ce)(ce)(ce)器地址及狀(zhuang)態,SF6/O2/溫濕度探測(ce)(ce)(ce)器在同一系(xi)統(tong)監控(kong); 2.6 大(da)(da)容量儲(chu)存芯片(pian),循環記錄(lu)報警(jing)信(xin)息,大(da)(da)可記錄(lu)50000條(tiao); 2.7 RS485上傳(chuan)接(jie)口(kou)(kou)(kou),標準modbus Rtu通(tong)訊協議。

2.8 關鍵參數(shu)(shu),加(jia)密設(she)(she)定(ding),防止誤操作 2.9 多可(ke)(ke)(ke)(ke)(ke)選配(pei)7組繼(ji)電(dian)器(qi),繼(ji)電(dian)器(qi)控制方式(shi)可(ke)(ke)(ke)(ke)(ke)軟件(jian)設(she)(she)置(zhi) 2.10 具有(you) 年-月(yue)-日(ri)(ri)-時-分-秒設(she)(she)置(zhi)功(gong)能(neng)(neng)(neng),并(bing)且帶有(you)每(mei)周七(qi)天分別(bie)顯示功(gong)能(neng)(neng)(neng) 壁(bi)掛式(shi)SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)報(bao)(bao)(bao)(bao)警(jing)主(zhu)機_SF6氧(yang)氣(qi)(qi)(qi)(qi)一(yi)體(ti)(ti)式(shi)探測器(qi)_SF6泄漏在線(xian)監測報(bao)(bao)(bao)(bao)警(jing)系(xi)(xi)統(tong)_SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)在線(xian)監測報(bao)(bao)(bao)(bao)警(jing)裝(zhuang)置(zhi)_SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)在線(xian)監測報(bao)(bao)(bao)(bao)警(jing)系(xi)(xi)統(tong) 三(san)章:主(zhu)要技術指標 3.1 壁(bi)掛式(shi)主(zhu)機技術指標(DX6000H型) 3.1.1 工(gong)作電(dian)壓: AC220V±15%,50Hz±1% 3.1.2 信號輸(shu)出: RS485 modbus_RTU 協議輸(shu)出 3.1.3 工(gong)作溫度(du): -20℃~+55℃ 3.1.4 工(gong)作濕(shi)度(du): ≤93%RH 3.1.5 顯示方式(shi): 列表顯示,每(mei)頁顯示8組或10組數(shu)(shu)據(每(mei)組包括SF6/02/溫度(du)/濕(shi)度(du)四種(zhong)數(shu)(shu)據和兩種(zhong)數(shu)(shu)據狀態) 3.1.6 上傳參數(shu)(shu): 默(mo)(mo)(mo)認ID 1(可(ke)(ke)(ke)(ke)(ke)調(diao)),默(mo)(mo)(mo)認波特率9600(可(ke)(ke)(ke)(ke)(ke)調(diao)) 3.1.7 人(ren)體(ti)(ti)感應:默(mo)(mo)(mo)認開(kai)(kai)啟感應亮(liang)(liang)屏(ping)功(gong)能(neng)(neng)(neng) 3.1.8 屏(ping)幕保護:默(mo)(mo)(mo)認開(kai)(kai)啟亮(liang)(liang)屏(ping)5分鐘后自動息屏(ping),人(ren)體(ti)(ti)感應或觸摸可(ke)(ke)(ke)(ke)(ke)亮(liang)(liang)屏(ping) 3.1.9 排(pai)風(feng)(feng)功(gong)能(neng)(neng)(neng):自動排(pai)風(feng)(feng),定(ding)時排(pai)風(feng)(feng),手動排(pai)風(feng)(feng),延(yan)時排(pai)風(feng)(feng),手動排(pai)風(feng)(feng)可(ke)(ke)(ke)(ke)(ke)設(she)(she)置(zhi)低1s,大12H,自動排(pai)風(feng)(feng)分為12組,可(ke)(ke)(ke)(ke)(ke)設(she)(she)置(zhi)開(kai)(kai)啟組數(shu)(shu)、開(kai)(kai)啟日(ri)(ri)期、開(kai)(kai)啟時間及(ji)啟動時間(啟動時間可(ke)(ke)(ke)(ke)(ke)更改(gai))功(gong)能(neng)(neng)(neng) sf6氣(qi)(qi)(qi)(qi)體(ti)(ti)報(bao)(bao)(bao)(bao)警(jing)裝(zhuang)置(zhi)_SF6氣(qi)(qi)(qi)(qi)體(ti)(ti)報(bao)(bao)(bao)(bao)警(jing)器(qi)_SF6報(bao)(bao)(bao)(bao)警(jing)裝(zhuang)置(zhi)_SF6報(bao)(bao)(bao)(bao)警(jing)主(zhu)機_SF6報(bao)(bao)(bao)(bao)警(jing)器(qi)。

SF6行業(ye)安全法規摘錄 ■191條 裝(zhuang)有SF6設(she)備的配電(dian)裝(zhuang)置室(shi)(shi)和(he)SF6氣(qi)體(ti)實驗室(shi)(shi),必須裝(zhuang)設(she)強力通風裝(zhuang)置。風口應設(she)置在(zai)室(shi)(shi)內低部。■192條 在(zai)室(shi)(shi)內,設(she)備充裝(zhuang)SF6氣(qi)體(ti)時(shi),周圍環境相對濕度應≤80%,同(tong)時(shi)必須開啟通風系(xi)統,并避(bi)免SF6氣(qi)體(ti)漏泄到工作區。工作區空(kong)氣(qi)中(zhong)SF6氣(qi)體(ti)含(han)量(liang)不(bu)得超(chao)過1000ppm。■196條 工作人員進(jin)入SF6配電(dian)裝(zhuang)置室(shi)(shi),必須先通風15min,并用(yong)檢(jian)漏儀(yi)測(ce)量(liang)SF6氣(qi)體(ti)含(han)量(liang)。盡(jin)量(liang)避(bi)免一人進(jin)入SF6配電(dian)裝(zhuang)置室(shi)(shi)進(jin)行巡視,不(bu)準(zhun)一人進(jin)入從事檢(jian)修工作。■198條 進(jin)入SF6配電(dian)裝(zhuang)置室(shi)(shi)低位區或電(dian)纜溝進(jin)行工作應先檢(jian)測(ce)含(han)氧(yang)量(liang)(不(bu)低于18%)和(he)SF6氣(qi)體(ti)含(han)量(liang)是否(fou)合格

高壓配電柜sf6濃度監測系統監控主機多少錢 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 高壓配電柜sf6濃度監測系統監控主機多少錢

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地址:濟南市高新技術(shu)開發(fa)區花園路東首

電話:15376190119

郵箱(xiang):sddx0001@163.com