核電站sf6在線泄露報警系統報警主機多少錢SF6報警

發布時間:2024-01-09 00:29:09       發布人:dxdz  瀏覽量:

核電站sf6在線泄露報警系統報警主機多少錢SF6報警

SF6氣(qi)(qi)體(ti)(ti)泄(xie)漏(lou)監(jian)控子(zi)系統主要(yao)對(dui)SF6氣(qi)(qi)體(ti)(ti)為絕緣介(jie)質的高(gao)壓(ya)電(dian)(dian)器設備(bei)場所內(nei)(nei)進行(xing)環(huan)境監(jian)測。當場所內(nei)(nei)設備(bei)發生(sheng)SF6氣(qi)(qi)體(ti)(ti)泄(xie)漏(lou)時(shi)(shi),由于(yu)(yu)(yu)SF6氣(qi)(qi)體(ti)(ti)的密度(du)是空(kong)氣(qi)(qi)的5倍,積累(lei)于(yu)(yu)(yu)底層空(kong)間,并(bing)造成局部(bu)缺氧(yang),引(yin)起嚴重事故(gu)。為此(ci):《電(dian)(dian)業安(an)全工(gong)(gong)作(zuo)(zuo)規程》(發電(dian)(dian)廠和(he)變(bian)電(dian)(dian)站部(bu)分)特別(bie)規定,工(gong)(gong)作(zuo)(zuo)人員進入SF6配電(dian)(dian)裝置(zhi)室低位(wei)區或電(dian)(dian)纜溝進行(xing)工(gong)(gong)作(zuo)(zuo)必須(xu)保證(zheng)SF6氣(qi)(qi)體(ti)(ti)濃度(du)小于(yu)(yu)(yu)1000ppm,含(han)氧(yang)量不低于(yu)(yu)(yu)18%及周圍環(huan)境相對(dui)濕(shi)度(du)80%,同(tong)時(shi)(shi)必須(xu)開(kai)啟通風系統。SF6+O2雙氣(qi)(qi)體(ti)(ti)探(tan)測器_SF6+O2氣(qi)(qi)體(ti)(ti)探(tan)測器_SF6+O2探(tan)測器_SF6+O2雙氣(qi)(qi)體(ti)(ti)探(tan)頭_SF6+O2氣(qi)(qi)體(ti)(ti)探(tan)頭_sf6氣(qi)(qi)體(ti)(ti)檢測儀(yi)

主要功(gong)能監(jian)控報警(jing)(jing)主機(ji)主要用于對下采(cai)(cai)集(ji)實時(shi)數(shu)(shu)(shu)據(ju)(ju)(包括控制器在內(nei)),對這(zhe)些數(shu)(shu)(shu)據(ju)(ju)進(jin)行分(fen)析(xi)和(he)管(guan)理,具有判斷現場數(shu)(shu)(shu)據(ju)(ju)是否超(chao)出(chu)設(she)(she)(she)定(ding)報警(jing)(jing)閥(fa)值(zhi)的(de)功(gong)能,超(chao)出(chu)則進(jin)行報警(jing)(jing)輸(shu)出(chu),啟(qi)動(dong)風機(ji)進(jin)行通風或啟(qi)動(dong)除濕進(jin)行除濕,同時(shi)聲光(guang)報警(jing)(jing)器進(jin)入報警(jing)(jing)狀態,并能接收入口處人員入室(shi)啟(qi)動(dong)風機(ji)進(jin)行通風的(de)功(gong)能。并可(ke)隨時(shi)接收一(yi)體化(hua)信息平臺的(de)訪問; 監(jian)控報警(jing)(jing)主機(ji)的(de)液晶(jing)(jing)顯示屏(ping)顯示現場實時(shi)數(shu)(shu)(shu)據(ju)(ju)、歷史數(shu)(shu)(shu)據(ju)(ju)、歷史報警(jing)(jing)數(shu)(shu)(shu)據(ju)(ju)和(he)報警(jing)(jing)時(shi)間等各種參(can)數(shu)(shu)(shu);還可(ke)采(cai)(cai)用鍵盤(pan)/觸模屏(ping)實現項目設(she)(she)(she)置(zhi)(zhi)、時(shi)間設(she)(she)(she)置(zhi)(zhi)、閥(fa)值(zhi)設(she)(she)(she)置(zhi)(zhi)、定(ding)時(shi)采(cai)(cai)集(ji)設(she)(she)(she)置(zhi)(zhi)、定(ding)時(shi)啟(qi)動(dong)風機(ji)設(she)(she)(she)置(zhi)(zhi),還設(she)(she)(she)有人體感應啟(qi)動(dong)液晶(jing)(jing)顯示屏(ping)背光(guang)及語(yu)音(yin)播(bo)報實時(shi)數(shu)(shu)(shu)據(ju)(ju)等多(duo)種配(pei)置(zhi)(zhi)和(he)管(guan)理功(gong)能。并能支持(chi)外(wai)置(zhi)(zhi)顯示屏(ping)狀態顯示及語(yu)音(yin)播(bo)報功(gong)能;

DX6000H型SF6 在(zai)線(xian)監(jian)(jian)測(ce)(ce)報(bao)警系統(tong)適用于配(pei)電室、開關站、光伏發電廠、海(hai)上風(feng)電場、10KV、35KV、220KV開關柜、GIS室等(deng)場所;設(she)備監(jian)(jian)測(ce)(ce)精度(du)高、范圍廣、功能全(quan),具有良好(hao)的擴展(zhan)性 2.1 采用1024*600觸摸(mo)屏,全(quan)中文菜單操作,界面友好(hao),操作簡單; 2.2 設(she)備集(ji)成三(san)組485接(jie)(jie)口,采用插(cha)拔式接(jie)(jie)線(xian)端子接(jie)(jie)線(xian)簡單,具有良好(hao)的抗干擾能力(li),總線(xian)通(tong)訊,布線(xian)經濟,安裝(zhuang)方便; 2.3 三(san)組DC24V接(jie)(jie)口,可選配(pei)DC3.3V、DC5V、DC12V電壓輸(shu)出, 2.4 自(zi)(zi)動(dong)故障檢測(ce)(ce),并能用中文顯示處準(zhun)確的故障部位及類型; 2.5 自(zi)(zi)動(dong)檢索(suo)探(tan)測(ce)(ce)器(qi)地址及狀態,SF6/O2/溫濕度(du)探(tan)測(ce)(ce)器(qi)在(zai)同一系統(tong)監(jian)(jian)控; 2.6 大容量(liang)儲存芯片,循(xun)環記錄報(bao)警信息,大可記錄50000條; 2.7 RS485上傳接(jie)(jie)口,標(biao)準(zhun)modbus Rtu通(tong)訊協議。

2.8 關鍵參(can)數(shu)(shu),加(jia)密(mi)設(she)定,防止誤操(cao)作(zuo)(zuo) 2.9 多可(ke)(ke)(ke)(ke)選(xuan)配7組繼電器,繼電器控制方(fang)式(shi)可(ke)(ke)(ke)(ke)軟件(jian)設(she)置(zhi) 2.10 具有 年-月-日(ri)-時(shi)-分(fen)-秒設(she)置(zhi)功(gong)能(neng)(neng)(neng),并(bing)且帶(dai)有每(mei)周七(qi)天分(fen)別顯(xian)示功(gong)能(neng)(neng)(neng) 壁掛式(shi)SF6氣(qi)體報(bao)(bao)警(jing)(jing)主(zhu)機(ji)_SF6氧氣(qi)一體式(shi)探測(ce)器_SF6泄漏在線監(jian)測(ce)報(bao)(bao)警(jing)(jing)系統_SF6氣(qi)體在線監(jian)測(ce)報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)_SF6氣(qi)體在線監(jian)測(ce)報(bao)(bao)警(jing)(jing)系統 三章:主(zhu)要技(ji)術指標 3.1 壁掛式(shi)主(zhu)機(ji)技(ji)術指標(DX6000H型(xing)) 3.1.1 工(gong)作(zuo)(zuo)電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸出: RS485 modbus_RTU 協議輸出 3.1.3 工(gong)作(zuo)(zuo)溫度(du)(du)(du): -20℃~+55℃ 3.1.4 工(gong)作(zuo)(zuo)濕度(du)(du)(du): ≤93%RH 3.1.5 顯(xian)示方(fang)式(shi): 列表顯(xian)示,每(mei)頁顯(xian)示8組或10組數(shu)(shu)據(ju)(ju)(每(mei)組包(bao)括SF6/02/溫度(du)(du)(du)/濕度(du)(du)(du)四種數(shu)(shu)據(ju)(ju)和(he)兩種數(shu)(shu)據(ju)(ju)狀態) 3.1.6 上傳參(can)數(shu)(shu): 默認(ren)ID 1(可(ke)(ke)(ke)(ke)調),默認(ren)波特率9600(可(ke)(ke)(ke)(ke)調) 3.1.7 人體感(gan)應(ying):默認(ren)開(kai)啟(qi)(qi)感(gan)應(ying)亮(liang)屏(ping)(ping)功(gong)能(neng)(neng)(neng) 3.1.8 屏(ping)(ping)幕(mu)保護:默認(ren)開(kai)啟(qi)(qi)亮(liang)屏(ping)(ping)5分(fen)鐘后自動(dong)息屏(ping)(ping),人體感(gan)應(ying)或觸摸可(ke)(ke)(ke)(ke)亮(liang)屏(ping)(ping) 3.1.9 排風(feng)功(gong)能(neng)(neng)(neng):自動(dong)排風(feng),定時(shi)排風(feng),手動(dong)排風(feng),延(yan)時(shi)排風(feng),手動(dong)排風(feng)可(ke)(ke)(ke)(ke)設(she)置(zhi)低1s,大(da)12H,自動(dong)排風(feng)分(fen)為12組,可(ke)(ke)(ke)(ke)設(she)置(zhi)開(kai)啟(qi)(qi)組數(shu)(shu)、開(kai)啟(qi)(qi)日(ri)期、開(kai)啟(qi)(qi)時(shi)間(jian)及(ji)啟(qi)(qi)動(dong)時(shi)間(jian)(啟(qi)(qi)動(dong)時(shi)間(jian)可(ke)(ke)(ke)(ke)更改)功(gong)能(neng)(neng)(neng) sf6氣(qi)體報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)_SF6氣(qi)體報(bao)(bao)警(jing)(jing)器_SF6報(bao)(bao)警(jing)(jing)裝(zhuang)置(zhi)_SF6報(bao)(bao)警(jing)(jing)主(zhu)機(ji)_SF6報(bao)(bao)警(jing)(jing)器。

SF6行(xing)(xing)業(ye)安全法規摘錄 ■191條(tiao) 裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)有SF6設(she)(she)(she)備的配電裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)置(zhi)(zhi)室(shi)和(he)SF6氣體(ti)實驗室(shi),必(bi)須裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)設(she)(she)(she)強(qiang)力通風裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)置(zhi)(zhi)。風口應(ying)設(she)(she)(she)置(zhi)(zhi)在室(shi)內低(di)部(bu)。■192條(tiao) 在室(shi)內,設(she)(she)(she)備充裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)SF6氣體(ti)時,周圍環境相(xiang)對濕(shi)度應(ying)≤80%,同時必(bi)須開啟通風系統(tong),并(bing)避免SF6氣體(ti)漏泄(xie)到工作(zuo)區。工作(zuo)區空氣中SF6氣體(ti)含(han)量(liang)(liang)(liang)不得超過1000ppm。■196條(tiao) 工作(zuo)人員進(jin)入(ru)(ru)SF6配電裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)置(zhi)(zhi)室(shi),必(bi)須先通風15min,并(bing)用檢(jian)漏儀測量(liang)(liang)(liang)SF6氣體(ti)含(han)量(liang)(liang)(liang)。盡量(liang)(liang)(liang)避免一(yi)人進(jin)入(ru)(ru)SF6配電裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)置(zhi)(zhi)室(shi)進(jin)行(xing)(xing)巡視,不準(zhun)一(yi)人進(jin)入(ru)(ru)從事(shi)檢(jian)修工作(zuo)。■198條(tiao) 進(jin)入(ru)(ru)SF6配電裝(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)(zhuang)置(zhi)(zhi)室(shi)低(di)位(wei)區或電纜溝(gou)進(jin)行(xing)(xing)工作(zuo)應(ying)先檢(jian)測含(han)氧量(liang)(liang)(liang)(不低(di)于18%)和(he)SF6氣體(ti)含(han)量(liang)(liang)(liang)是否合格

核電站sf6在線泄露報警系統報警主機多少錢SF6報警 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 核電站sf6在線泄露報警系統報警主機多少錢SF6報警