久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱(re)線(xian)電話:15376190119
您所在的位置: 主頁 ? 新聞動態 ? 常見問題解答

光伏站sf6泄露報警裝置報警裝置多少錢

發布時間:2023-11-26 11:28:18       發布人:dxdz  瀏覽量:

光伏站sf6泄露報警裝置報警裝置多少錢

本系統采用間歇式(shi)(shi)檢測模式(shi)(shi),進行(xing)在線監(jian)(jian)(jian)測其場所內(nei)SF6氣體濃度(du)(du)及O2含(han)量和環(huan)境(jing)溫(wen)度(du)(du)、濕(shi)度(du)(du)的狀態監(jian)(jian)(jian)測,當場所內(nei)SF6濃度(du)(du)及O2含(han)量和環(huan)境(jing)濕(shi)度(du)(du)發生變化時(shi),傳感器立(li)即響應這(zhe)些變化。實現對(dui)(dui)場所內(nei)SF6濃度(du)(du)及O2的含(han)量和環(huan)境(jing)溫(wen)度(du)(du)、濕(shi)度(du)(du)進行(xing)有效地監(jian)(jian)(jian)測。通(tong)(tong)過(guo)(guo)現場總線(RS485)由監(jian)(jian)(jian)控(kong)報(bao)警(jing)(jing)主機采集狀態參(can)數(shu),當場所內(nei)出現超限值(zhi)時(shi),進入預(yu)警(jing)(jing)聲光報(bao)警(jing)(jing)同(tong)時(shi)啟(qi)(qi)動(dong)(dong)(dong)風機進行(xing)通(tong)(tong)風換(huan)氣或(huo)啟(qi)(qi)動(dong)(dong)(dong)除濕(shi)機進行(xing)除濕(shi)。同(tong)時(shi)將狀態參(can)數(shu)上傳輸給監(jian)(jian)(jian)控(kong)中心(xin)。在監(jian)(jian)(jian)控(kong)中心(xin)電(dian)子地圖(tu)上進行(xing)定位及管理和環(huan)境(jing)參(can)量超過(guo)(guo)預(yu)設(she)值(zhi)時(shi)發出視聽告警(jing)(jing)在電(dian)子地圖(tu)界(jie)面(mian)上閃爍(shuo)顯示(shi),按照預(yu)設(she)置聯(lian)動(dong)(dong)(dong)方(fang)案,對(dui)(dui)通(tong)(tong)道門體、風機以及水泵等進行(xing)管理;以及通(tong)(tong)過(guo)(guo)語(yu)音、短信方(fang)式(shi)(shi)自動(dong)(dong)(dong)通(tong)(tong)知值(zhi)班維護人(ren)員

雙氣(qi)體(ti)檢測器主要由(you)傳感(gan)器、單(dan)片(pian)機、運算(suan)(suan)放大(da)(da)電路、通訊芯(xin)片(pian)等組成。傳感(gan)器將氣(qi)體(ti)濃度轉(zhuan)換(huan)為模(mo)擬電信(xin)(xin)號(hao),然后將模(mo)擬電信(xin)(xin)號(hao)通過運算(suan)(suan)放大(da)(da)電路、單(dan)片(pian)機轉(zhuan)換(huan)為數字信(xin)(xin)號(hao),后通過通訊芯(xin)片(pian)轉(zhuan)換(huan)為modbus RTU標準信(xin)(xin)號(hao),上傳給控制(zhi)器。

DX6000H型SF6 在線監測(ce)報(bao)警(jing)系(xi)統(tong)適用(yong)于配電室、開(kai)關站(zhan)、光伏發(fa)電廠、海上風(feng)電場、10KV、35KV、220KV開(kai)關柜、GIS室等(deng)場所;設(she)備監測(ce)精度(du)高、范圍(wei)廣(guang)、功(gong)能全,具(ju)有良(liang)(liang)好(hao)(hao)的擴(kuo)展性  2.1 采用(yong)1024*600觸摸屏,全中(zhong)文(wen)菜單(dan)操作(zuo),界(jie)面(mian)友好(hao)(hao),操作(zuo)簡單(dan); 2.2 設(she)備集成三組485接(jie)口(kou),采用(yong)插拔式(shi)接(jie)線端子接(jie)線簡單(dan),具(ju)有良(liang)(liang)好(hao)(hao)的抗干擾(rao)能力,總(zong)線通訊,布線經(jing)濟(ji),安裝方(fang)便; 2.3 三組DC24V接(jie)口(kou),可選配DC3.3V、DC5V、DC12V電壓輸出, 2.4 自(zi)動(dong)(dong)故障(zhang)檢測(ce),并能用(yong)中(zhong)文(wen)顯示處準確(que)的故障(zhang)部位(wei)及類型; 2.5 自(zi)動(dong)(dong)檢索探測(ce)器地址及狀(zhuang)態(tai),SF6/O2/溫濕度(du)探測(ce)器在同一(yi)系(xi)統(tong)監控; 2.6 大容量儲(chu)存芯片,循環記錄報(bao)警(jing)信息(xi),大可記錄50000條(tiao); 2.7 RS485上傳接(jie)口(kou),標(biao)準modbus Rtu通訊協議。

2.8 關鍵參數(shu),加密(mi)設(she)(she)定,防止誤操作(zuo) 2.9 多可(ke)(ke)選(xuan)配7組(zu)繼電器(qi)(qi),繼電器(qi)(qi)控(kong)制方(fang)式(shi)(shi)(shi)可(ke)(ke)軟件設(she)(she)置(zhi)(zhi)(zhi) 2.10 具有(you)(you) 年-月-日-時(shi)-分(fen)-秒設(she)(she)置(zhi)(zhi)(zhi)功能(neng)(neng),并且帶有(you)(you)每周(zhou)七天分(fen)別(bie)顯(xian)示(shi)功能(neng)(neng) 壁(bi)掛式(shi)(shi)(shi)SF6氣體(ti)報(bao)警(jing)(jing)主機(ji)(ji)_SF6氧氣一體(ti)式(shi)(shi)(shi)探測器(qi)(qi)_SF6泄漏在線監測報(bao)警(jing)(jing)系統(tong)(tong)_SF6氣體(ti)在線監測報(bao)警(jing)(jing)裝置(zhi)(zhi)(zhi)_SF6氣體(ti)在線監測報(bao)警(jing)(jing)系統(tong)(tong) 三章:主要技術指標 3.1 壁(bi)掛式(shi)(shi)(shi)主機(ji)(ji)技術指標(DX6000H型) 3.1.1 工作(zuo)電壓: AC220V±15%,50Hz±1% 3.1.2 信號(hao)輸出: RS485 modbus_RTU 協議輸出 3.1.3 工作(zuo)溫度(du)(du): -20℃~+55℃ 3.1.4 工作(zuo)濕度(du)(du): ≤93%RH 3.1.5 顯(xian)示(shi)方(fang)式(shi)(shi)(shi): 列表(biao)顯(xian)示(shi),每頁顯(xian)示(shi)8組(zu)或(huo)10組(zu)數(shu)據(每組(zu)包(bao)括(kuo)SF6/02/溫度(du)(du)/濕度(du)(du)四種(zhong)數(shu)據和兩(liang)種(zhong)數(shu)據狀態(tai)) 3.1.6 上傳(chuan)參數(shu): 默認(ren)(ren)ID 1(可(ke)(ke)調(diao)(diao)),默認(ren)(ren)波特率9600(可(ke)(ke)調(diao)(diao)) 3.1.7 人(ren)體(ti)感應:默認(ren)(ren)開(kai)啟感應亮(liang)屏(ping)功能(neng)(neng) 3.1.8 屏(ping)幕保護(hu):默認(ren)(ren)開(kai)啟亮(liang)屏(ping)5分(fen)鐘(zhong)后自動(dong)(dong)息屏(ping),人(ren)體(ti)感應或(huo)觸摸可(ke)(ke)亮(liang)屏(ping) 3.1.9 排(pai)(pai)風(feng)功能(neng)(neng):自動(dong)(dong)排(pai)(pai)風(feng),定時(shi)排(pai)(pai)風(feng),手動(dong)(dong)排(pai)(pai)風(feng),延時(shi)排(pai)(pai)風(feng),手動(dong)(dong)排(pai)(pai)風(feng)可(ke)(ke)設(she)(she)置(zhi)(zhi)(zhi)低1s,大12H,自動(dong)(dong)排(pai)(pai)風(feng)分(fen)為(wei)12組(zu),可(ke)(ke)設(she)(she)置(zhi)(zhi)(zhi)開(kai)啟組(zu)數(shu)、開(kai)啟日期、開(kai)啟時(shi)間及啟動(dong)(dong)時(shi)間(啟動(dong)(dong)時(shi)間可(ke)(ke)更(geng)改)功能(neng)(neng) sf6氣體(ti)報(bao)警(jing)(jing)裝置(zhi)(zhi)(zhi)_SF6氣體(ti)報(bao)警(jing)(jing)器(qi)(qi)_SF6報(bao)警(jing)(jing)裝置(zhi)(zhi)(zhi)_SF6報(bao)警(jing)(jing)主機(ji)(ji)_SF6報(bao)警(jing)(jing)器(qi)(qi)。

SF6行(xing)業安全法規(gui)摘(zhai)錄 ■191條 裝(zhuang)(zhuang)有(you)SF6設(she)備的配(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)和SF6氣(qi)(qi)體(ti)實驗室(shi),必(bi)須(xu)裝(zhuang)(zhuang)設(she)強力通(tong)風裝(zhuang)(zhuang)置(zhi)(zhi)。風口(kou)應(ying)(ying)設(she)置(zhi)(zhi)在室(shi)內(nei)低(di)(di)部。■192條 在室(shi)內(nei),設(she)備充裝(zhuang)(zhuang)SF6氣(qi)(qi)體(ti)時,周(zhou)圍(wei)環境(jing)相(xiang)對濕度(du)應(ying)(ying)≤80%,同時必(bi)須(xu)開啟(qi)通(tong)風系統,并避(bi)免(mian)SF6氣(qi)(qi)體(ti)漏泄到工(gong)作(zuo)區(qu)。工(gong)作(zuo)區(qu)空(kong)氣(qi)(qi)中SF6氣(qi)(qi)體(ti)含(han)(han)量不(bu)得超過(guo)1000ppm。■196條 工(gong)作(zuo)人(ren)員進入(ru)(ru)SF6配(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)(zhi)室(shi),必(bi)須(xu)先通(tong)風15min,并用(yong)檢(jian)漏儀(yi)測量SF6氣(qi)(qi)體(ti)含(han)(han)量。盡量避(bi)免(mian)一人(ren)進入(ru)(ru)SF6配(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)進行(xing)巡視,不(bu)準一人(ren)進入(ru)(ru)從事檢(jian)修工(gong)作(zuo)。■198條 進入(ru)(ru)SF6配(pei)電(dian)(dian)裝(zhuang)(zhuang)置(zhi)(zhi)室(shi)低(di)(di)位區(qu)或電(dian)(dian)纜(lan)溝進行(xing)工(gong)作(zuo)應(ying)(ying)先檢(jian)測含(han)(han)氧量(不(bu)低(di)(di)于18%)和SF6氣(qi)(qi)體(ti)含(han)(han)量是否合格(ge)

光伏站sf6泄露報警裝置報警裝置多少錢 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6泄露報警裝置報警裝置多少錢

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地址(zhi):濟南市高新技(ji)術(shu)開發區花園路東首

電話(hua):15376190119

郵箱:sddx0001@163.com