久久久久国产综合av天堂_国产色噜噜噜在线精品_无码人妻丰满熟妇区BBBBXXXX_五月播播

歡迎您進入濟南東信電子科技有限公司氣體檢測報警系統官方網站
熱線電話:15376190119
您所在的位置: 主頁 ? 新聞動態 ? 常見問題解答

光伏站sf6在線泄漏報警系統報警器多少錢

發布時間:2023-10-22 11:26:00       發布人:147小編  瀏覽量:

光伏站sf6在線泄漏報警系統報警器多少錢

SF6氣(qi)(qi)體(ti)(ti)(ti)泄漏監控子系統(tong)主要對SF6氣(qi)(qi)體(ti)(ti)(ti)為(wei)(wei)絕緣介質的高壓電(dian)(dian)器設(she)備(bei)場所內進行(xing)環境監測(ce)。當場所內設(she)備(bei)發生SF6氣(qi)(qi)體(ti)(ti)(ti)泄漏時,由(you)于(yu)SF6氣(qi)(qi)體(ti)(ti)(ti)的密(mi)度(du)是空氣(qi)(qi)的5倍,積(ji)累于(yu)底層空間,并造成局(ju)部缺氧,引(yin)起嚴重(zhong)事故。為(wei)(wei)此:《電(dian)(dian)業安全工(gong)作(zuo)規程》(發電(dian)(dian)廠和變電(dian)(dian)站部分)特(te)別規定,工(gong)作(zuo)人員進入SF6配電(dian)(dian)裝置室低位(wei)區或電(dian)(dian)纜溝進行(xing)工(gong)作(zuo)必(bi)須保證SF6氣(qi)(qi)體(ti)(ti)(ti)濃(nong)度(du)小于(yu)1000ppm,含(han)氧量(liang)不低于(yu)18%及周圍環境相對濕度(du)80%,同時必(bi)須開啟(qi)通(tong)風系統(tong)。SF6+O2雙氣(qi)(qi)體(ti)(ti)(ti)探(tan)(tan)測(ce)器_SF6+O2氣(qi)(qi)體(ti)(ti)(ti)探(tan)(tan)測(ce)器_SF6+O2探(tan)(tan)測(ce)器_SF6+O2雙氣(qi)(qi)體(ti)(ti)(ti)探(tan)(tan)頭(tou)_SF6+O2氣(qi)(qi)體(ti)(ti)(ti)探(tan)(tan)頭(tou)_sf6氣(qi)(qi)體(ti)(ti)(ti)檢測(ce)儀

顯(xian)(xian)示(shi)(shi)屏由控(kong)制單元(yuan)、通信(xin)單元(yuan)、人(ren)體感應啟(qi)動(dong)顯(xian)(xian)示(shi)(shi)及(ji)(ji)語音(yin)播(bo)報(bao)單元(yuan)組成,當人(ren)體感應器感應到人(ren)身(shen)啟(qi)動(dong)信(xin)息,將啟(qi)動(dong)信(xin)息通過485總線(xian)傳(chuan)輸給監控(kong)主機,由監控(kong)主機控(kong)制顯(xian)(xian)示(shi)(shi)單元(yuan)顯(xian)(xian)示(shi)(shi)室內SF6高值(zhi)及(ji)(ji)對(dui)應機號(hao)和(he)O2低值(zhi)及(ji)(ji)對(dui)應機號(hao),后顯(xian)(xian)示(shi)(shi)室內是否(fou)安全,同時(shi)(shi)語音(yin)播(bo)報(bao)顯(xian)(xian)示(shi)(shi)內容。專為多個入(ru)(ru)口(kou)而設計,一般安裝(zhuang)在(zai)(zai)場(chang)所入(ru)(ru)口(kou)處,為工作人(ren)員(yuan)在(zai)(zai)進入(ru)(ru)每個入(ru)(ru)口(kou)時(shi)(shi)都(dou)能及(ji)(ji)時(shi)(shi)播(bo)報(bao)和(he)顯(xian)(xian)示(shi)(shi)場(chang)所內狀(zhuang)態和(he)安全情況。

DX6000H型(xing)SF6 在(zai)線(xian)(xian)監(jian)測報(bao)警(jing)(jing)系統(tong)適用于(yu)配(pei)電(dian)(dian)室(shi)、開(kai)關(guan)站、光伏發(fa)電(dian)(dian)廠、海(hai)上風電(dian)(dian)場(chang)、10KV、35KV、220KV開(kai)關(guan)柜、GIS室(shi)等場(chang)所;設備(bei)監(jian)測精度(du)高、范(fan)圍廣、功能全,具有良好的(de)擴展性 2.1 采用1024*600觸摸(mo)屏,全中文菜單操作,界(jie)面友好,操作簡(jian)單; 2.2 設備(bei)集成(cheng)三組485接(jie)口,采用插拔式接(jie)線(xian)(xian)端子接(jie)線(xian)(xian)簡(jian)單,具有良好的(de)抗干擾(rao)能力,總線(xian)(xian)通訊,布線(xian)(xian)經濟,安裝方便; 2.3 三組DC24V接(jie)口,可選(xuan)配(pei)DC3.3V、DC5V、DC12V電(dian)(dian)壓輸出, 2.4 自動故障檢(jian)測,并(bing)能用中文顯示處準確的(de)故障部(bu)位(wei)及類(lei)型(xing); 2.5 自動檢(jian)索探測器地(di)址及狀態,SF6/O2/溫濕(shi)度(du)探測器在(zai)同一系統(tong)監(jian)控; 2.6 大容量儲存芯片,循環記(ji)錄(lu)報(bao)警(jing)(jing)信息,大可記(ji)錄(lu)50000條(tiao); 2.7 RS485上傳接(jie)口,標(biao)準modbus Rtu通訊協議。

2.8 關鍵參數(shu)(shu),加密設(she)(she)定,防(fang)止誤(wu)操作 2.9 多可(ke)選配(pei)7組(zu)(zu)繼電器(qi)(qi)(qi)(qi),繼電器(qi)(qi)(qi)(qi)控制方式(shi)可(ke)軟(ruan)件設(she)(she)置(zhi)(zhi)(zhi) 2.10 具有 年-月-日-時-分(fen)-秒設(she)(she)置(zhi)(zhi)(zhi)功(gong)能(neng)(neng),并(bing)且帶有每周七天分(fen)別顯(xian)示(shi)(shi)功(gong)能(neng)(neng) 壁掛式(shi)SF6氣(qi)(qi)(qi)(qi)體(ti)報(bao)(bao)(bao)警(jing)(jing)主(zhu)機_SF6氧氣(qi)(qi)(qi)(qi)一體(ti)式(shi)探測(ce)(ce)器(qi)(qi)(qi)(qi)_SF6泄(xie)漏在(zai)線(xian)(xian)監測(ce)(ce)報(bao)(bao)(bao)警(jing)(jing)系統_SF6氣(qi)(qi)(qi)(qi)體(ti)在(zai)線(xian)(xian)監測(ce)(ce)報(bao)(bao)(bao)警(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6氣(qi)(qi)(qi)(qi)體(ti)在(zai)線(xian)(xian)監測(ce)(ce)報(bao)(bao)(bao)警(jing)(jing)系統 三(san)章:主(zhu)要(yao)技(ji)(ji)術(shu)指標 3.1 壁掛式(shi)主(zhu)機技(ji)(ji)術(shu)指標(DX6000H型) 3.1.1 工(gong)作電壓: AC220V±15%,50Hz±1% 3.1.2 信號輸出: RS485 modbus_RTU 協議輸出 3.1.3 工(gong)作溫(wen)(wen)度(du)(du): -20℃~+55℃ 3.1.4 工(gong)作濕度(du)(du): ≤93%RH 3.1.5 顯(xian)示(shi)(shi)方式(shi): 列表顯(xian)示(shi)(shi),每頁顯(xian)示(shi)(shi)8組(zu)(zu)或(huo)10組(zu)(zu)數(shu)(shu)據(ju)(每組(zu)(zu)包括SF6/02/溫(wen)(wen)度(du)(du)/濕度(du)(du)四種數(shu)(shu)據(ju)和兩(liang)種數(shu)(shu)據(ju)狀態(tai)) 3.1.6 上傳參數(shu)(shu): 默認(ren)ID 1(可(ke)調),默認(ren)波特率9600(可(ke)調) 3.1.7 人(ren)體(ti)感應(ying):默認(ren)開(kai)啟(qi)感應(ying)亮(liang)(liang)屏(ping)(ping)(ping)功(gong)能(neng)(neng) 3.1.8 屏(ping)(ping)(ping)幕(mu)保護(hu):默認(ren)開(kai)啟(qi)亮(liang)(liang)屏(ping)(ping)(ping)5分(fen)鐘后自(zi)動(dong)(dong)(dong)息屏(ping)(ping)(ping),人(ren)體(ti)感應(ying)或(huo)觸摸可(ke)亮(liang)(liang)屏(ping)(ping)(ping) 3.1.9 排風(feng)(feng)(feng)(feng)功(gong)能(neng)(neng):自(zi)動(dong)(dong)(dong)排風(feng)(feng)(feng)(feng),定時排風(feng)(feng)(feng)(feng),手動(dong)(dong)(dong)排風(feng)(feng)(feng)(feng),延時排風(feng)(feng)(feng)(feng),手動(dong)(dong)(dong)排風(feng)(feng)(feng)(feng)可(ke)設(she)(she)置(zhi)(zhi)(zhi)低1s,大12H,自(zi)動(dong)(dong)(dong)排風(feng)(feng)(feng)(feng)分(fen)為12組(zu)(zu),可(ke)設(she)(she)置(zhi)(zhi)(zhi)開(kai)啟(qi)組(zu)(zu)數(shu)(shu)、開(kai)啟(qi)日期(qi)、開(kai)啟(qi)時間(jian)及(ji)啟(qi)動(dong)(dong)(dong)時間(jian)(啟(qi)動(dong)(dong)(dong)時間(jian)可(ke)更(geng)改)功(gong)能(neng)(neng) sf6氣(qi)(qi)(qi)(qi)體(ti)報(bao)(bao)(bao)警(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6氣(qi)(qi)(qi)(qi)體(ti)報(bao)(bao)(bao)警(jing)(jing)器(qi)(qi)(qi)(qi)_SF6報(bao)(bao)(bao)警(jing)(jing)裝(zhuang)(zhuang)置(zhi)(zhi)(zhi)_SF6報(bao)(bao)(bao)警(jing)(jing)主(zhu)機_SF6報(bao)(bao)(bao)警(jing)(jing)器(qi)(qi)(qi)(qi)。

SF6行(xing)(xing)業安全(quan)法規摘錄 ■191條(tiao)(tiao) 裝(zhuang)有SF6設(she)備的配(pei)(pei)電裝(zhuang)置(zhi)室(shi)和SF6氣(qi)體(ti)(ti)(ti)實驗室(shi),必(bi)須裝(zhuang)設(she)強力通風(feng)裝(zhuang)置(zhi)。風(feng)口應設(she)置(zhi)在室(shi)內(nei)(nei)低(di)部。■192條(tiao)(tiao) 在室(shi)內(nei)(nei),設(she)備充裝(zhuang)SF6氣(qi)體(ti)(ti)(ti)時,周圍環境(jing)相對濕度(du)應≤80%,同時必(bi)須開啟通風(feng)系統,并避免SF6氣(qi)體(ti)(ti)(ti)漏泄到工作區(qu)。工作區(qu)空氣(qi)中(zhong)SF6氣(qi)體(ti)(ti)(ti)含(han)量(liang)(liang)不得超過1000ppm。■196條(tiao)(tiao) 工作人員進(jin)入(ru)SF6配(pei)(pei)電裝(zhuang)置(zhi)室(shi),必(bi)須先通風(feng)15min,并用檢漏儀(yi)測量(liang)(liang)SF6氣(qi)體(ti)(ti)(ti)含(han)量(liang)(liang)。盡量(liang)(liang)避免一人進(jin)入(ru)SF6配(pei)(pei)電裝(zhuang)置(zhi)室(shi)進(jin)行(xing)(xing)巡視,不準一人進(jin)入(ru)從事檢修工作。■198條(tiao)(tiao) 進(jin)入(ru)SF6配(pei)(pei)電裝(zhuang)置(zhi)室(shi)低(di)位區(qu)或電纜(lan)溝進(jin)行(xing)(xing)工作應先檢測含(han)氧量(liang)(liang)(不低(di)于18%)和SF6氣(qi)體(ti)(ti)(ti)含(han)量(liang)(liang)是否合格

光伏站sf6在線泄漏報警系統報警器多少錢 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6在線泄漏報警系統報警器多少錢

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地址:濟(ji)南市高新(xin)技術開發區花園(yuan)路東首

電話:15376190119

郵箱(xiang):sddx0001@163.com