光伏站sf6泄漏報警器

發布時間:2023-11-16 20:27:40       發布人:dxdz  瀏覽量:

光伏站sf6泄漏報警器

SF6氣(qi)(qi)體(ti)泄漏監(jian)控(kong)子系統(tong)主要對(dui)SF6氣(qi)(qi)體(ti)為絕緣介質的高壓電(dian)(dian)器設(she)備場所內(nei)進行環境監(jian)測(ce)。當(dang)場所內(nei)設(she)備發(fa)生SF6氣(qi)(qi)體(ti)泄漏時(shi),由于SF6氣(qi)(qi)體(ti)的密度(du)(du)是空氣(qi)(qi)的5倍,積累于底層空間,并(bing)造成局部(bu)缺氧(yang),引起嚴(yan)重事故。為此:《電(dian)(dian)業安全工(gong)(gong)作規程》(發(fa)電(dian)(dian)廠和(he)變電(dian)(dian)站部(bu)分)特(te)別規定(ding),工(gong)(gong)作人員進入SF6配電(dian)(dian)裝置室低(di)位區或電(dian)(dian)纜(lan)溝進行工(gong)(gong)作必須(xu)保證SF6氣(qi)(qi)體(ti)濃度(du)(du)小于1000ppm,含氧(yang)量不低(di)于18%及周圍環境相對(dui)濕(shi)度(du)(du)80%,同時(shi)必須(xu)開啟通風系統(tong)。SF6+O2雙氣(qi)(qi)體(ti)探測(ce)器_SF6+O2氣(qi)(qi)體(ti)探測(ce)器_SF6+O2探測(ce)器_SF6+O2雙氣(qi)(qi)體(ti)探頭_SF6+O2氣(qi)(qi)體(ti)探頭_sf6氣(qi)(qi)體(ti)檢測(ce)儀

顯(xian)(xian)示(shi)(shi)屏(ping)由控制單(dan)元(yuan)(yuan)、通(tong)信單(dan)元(yuan)(yuan)、人(ren)體(ti)感(gan)應(ying)啟動(dong)顯(xian)(xian)示(shi)(shi)及(ji)語音(yin)播報單(dan)元(yuan)(yuan)組成,當人(ren)體(ti)感(gan)應(ying)器(qi)感(gan)應(ying)到人(ren)身(shen)啟動(dong)信息,將啟動(dong)信息通(tong)過485總(zong)線傳輸(shu)給監控主機,由監控主機控制顯(xian)(xian)示(shi)(shi)單(dan)元(yuan)(yuan)顯(xian)(xian)示(shi)(shi)室內(nei)SF6高值(zhi)及(ji)對(dui)應(ying)機號(hao)和(he)O2低值(zhi)及(ji)對(dui)應(ying)機號(hao),后(hou)顯(xian)(xian)示(shi)(shi)室內(nei)是(shi)否安全(quan),同時(shi)語音(yin)播報顯(xian)(xian)示(shi)(shi)內(nei)容(rong)。專為多個入(ru)口而(er)設(she)計,一般安裝在(zai)場(chang)(chang)所入(ru)口處,為工作人(ren)員在(zai)進入(ru)每個入(ru)口時(shi)都能及(ji)時(shi)播報和(he)顯(xian)(xian)示(shi)(shi)場(chang)(chang)所內(nei)狀態和(he)安全(quan)情(qing)況。

DX6000H型(xing)SF6 在線監(jian)(jian)測(ce)報(bao)警(jing)系(xi)(xi)統適用于配電(dian)室(shi)、開關站、光伏發(fa)電(dian)廠(chang)、海上風電(dian)場、10KV、35KV、220KV開關柜、GIS室(shi)等場所(suo);設(she)(she)備監(jian)(jian)測(ce)精度高、范圍廣、功能全(quan),具有良好(hao)的(de)(de)(de)擴(kuo)展性 2.1 采用1024*600觸摸屏,全(quan)中文(wen)菜單操(cao)作(zuo),界面友好(hao),操(cao)作(zuo)簡單; 2.2 設(she)(she)備集成三組485接(jie)(jie)口(kou),采用插拔(ba)式接(jie)(jie)線端(duan)子接(jie)(jie)線簡單,具有良好(hao)的(de)(de)(de)抗干擾能力,總線通訊(xun),布線經濟,安裝方便; 2.3 三組DC24V接(jie)(jie)口(kou),可選配DC3.3V、DC5V、DC12V電(dian)壓輸出, 2.4 自動故障(zhang)檢測(ce),并能用中文(wen)顯示(shi)處準(zhun)(zhun)確的(de)(de)(de)故障(zhang)部位及(ji)類型(xing); 2.5 自動檢索探(tan)測(ce)器地址及(ji)狀態,SF6/O2/溫濕度探(tan)測(ce)器在同一系(xi)(xi)統監(jian)(jian)控; 2.6 大(da)容(rong)量儲存芯片,循環記錄(lu)(lu)報(bao)警(jing)信息,大(da)可記錄(lu)(lu)50000條; 2.7 RS485上傳接(jie)(jie)口(kou),標準(zhun)(zhun)modbus Rtu通訊(xun)協議。

2.8 關(guan)鍵參數(shu),加密設定(ding),防(fang)止誤(wu)操作(zuo)(zuo)(zuo) 2.9 多(duo)可(ke)選配(pei)7組(zu)(zu)繼電(dian)器,繼電(dian)器控(kong)制方式(shi)可(ke)軟件設置(zhi)(zhi)(zhi)(zhi) 2.10 具有 年-月-日(ri)-時-分(fen)-秒設置(zhi)(zhi)(zhi)(zhi)功(gong)能(neng)(neng),并且帶有每周七天分(fen)別(bie)顯(xian)(xian)(xian)示(shi)功(gong)能(neng)(neng) 壁(bi)掛(gua)式(shi)SF6氣(qi)(qi)體(ti)報(bao)(bao)警主(zhu)機(ji)_SF6氧氣(qi)(qi)一體(ti)式(shi)探測(ce)器_SF6泄漏在(zai)(zai)線(xian)監(jian)測(ce)報(bao)(bao)警系統_SF6氣(qi)(qi)體(ti)在(zai)(zai)線(xian)監(jian)測(ce)報(bao)(bao)警裝(zhuang)置(zhi)(zhi)(zhi)(zhi)_SF6氣(qi)(qi)體(ti)在(zai)(zai)線(xian)監(jian)測(ce)報(bao)(bao)警系統 三章:主(zhu)要技術指標(biao) 3.1 壁(bi)掛(gua)式(shi)主(zhu)機(ji)技術指標(biao)(DX6000H型) 3.1.1 工(gong)作(zuo)(zuo)(zuo)電(dian)壓(ya): AC220V±15%,50Hz±1% 3.1.2 信號(hao)輸(shu)出: RS485 modbus_RTU 協議輸(shu)出 3.1.3 工(gong)作(zuo)(zuo)(zuo)溫(wen)度(du)(du): -20℃~+55℃ 3.1.4 工(gong)作(zuo)(zuo)(zuo)濕(shi)度(du)(du): ≤93%RH 3.1.5 顯(xian)(xian)(xian)示(shi)方式(shi): 列(lie)表顯(xian)(xian)(xian)示(shi),每頁顯(xian)(xian)(xian)示(shi)8組(zu)(zu)或(huo)10組(zu)(zu)數(shu)據(每組(zu)(zu)包(bao)括SF6/02/溫(wen)度(du)(du)/濕(shi)度(du)(du)四種數(shu)據和兩(liang)種數(shu)據狀態) 3.1.6 上傳參數(shu): 默認(ren)ID 1(可(ke)調(diao)),默認(ren)波(bo)特(te)率(lv)9600(可(ke)調(diao)) 3.1.7 人(ren)體(ti)感應(ying):默認(ren)開(kai)啟感應(ying)亮(liang)(liang)(liang)屏功(gong)能(neng)(neng) 3.1.8 屏幕保(bao)護:默認(ren)開(kai)啟亮(liang)(liang)(liang)屏5分(fen)鐘后自(zi)動(dong)息(xi)屏,人(ren)體(ti)感應(ying)或(huo)觸摸可(ke)亮(liang)(liang)(liang)屏 3.1.9 排(pai)(pai)(pai)風(feng)(feng)功(gong)能(neng)(neng):自(zi)動(dong)排(pai)(pai)(pai)風(feng)(feng),定(ding)時排(pai)(pai)(pai)風(feng)(feng),手動(dong)排(pai)(pai)(pai)風(feng)(feng),延(yan)時排(pai)(pai)(pai)風(feng)(feng),手動(dong)排(pai)(pai)(pai)風(feng)(feng)可(ke)設置(zhi)(zhi)(zhi)(zhi)低1s,大12H,自(zi)動(dong)排(pai)(pai)(pai)風(feng)(feng)分(fen)為12組(zu)(zu),可(ke)設置(zhi)(zhi)(zhi)(zhi)開(kai)啟組(zu)(zu)數(shu)、開(kai)啟日(ri)期(qi)、開(kai)啟時間(jian)(jian)及啟動(dong)時間(jian)(jian)(啟動(dong)時間(jian)(jian)可(ke)更(geng)改)功(gong)能(neng)(neng) sf6氣(qi)(qi)體(ti)報(bao)(bao)警裝(zhuang)置(zhi)(zhi)(zhi)(zhi)_SF6氣(qi)(qi)體(ti)報(bao)(bao)警器_SF6報(bao)(bao)警裝(zhuang)置(zhi)(zhi)(zhi)(zhi)_SF6報(bao)(bao)警主(zhu)機(ji)_SF6報(bao)(bao)警器。

SF6行業(ye)安全法規摘錄 ■191條 裝有SF6設(she)(she)備的(de)配電裝置(zhi)室(shi)和SF6氣(qi)體實驗室(shi),必須(xu)(xu)裝設(she)(she)強力通風(feng)(feng)(feng)裝置(zhi)。風(feng)(feng)(feng)口應(ying)設(she)(she)置(zhi)在室(shi)內(nei)低(di)部。■192條 在室(shi)內(nei),設(she)(she)備充裝SF6氣(qi)體時,周圍環境相對濕(shi)度應(ying)≤80%,同時必須(xu)(xu)開啟(qi)通風(feng)(feng)(feng)系(xi)統,并(bing)避免(mian)SF6氣(qi)體漏(lou)泄(xie)到工作(zuo)區。工作(zuo)區空(kong)氣(qi)中SF6氣(qi)體含量(liang)(liang)(liang)不(bu)得超過1000ppm。■196條 工作(zuo)人(ren)員進入(ru)(ru)SF6配電裝置(zhi)室(shi),必須(xu)(xu)先通風(feng)(feng)(feng)15min,并(bing)用檢(jian)(jian)漏(lou)儀測量(liang)(liang)(liang)SF6氣(qi)體含量(liang)(liang)(liang)。盡量(liang)(liang)(liang)避免(mian)一(yi)人(ren)進入(ru)(ru)SF6配電裝置(zhi)室(shi)進行巡視,不(bu)準一(yi)人(ren)進入(ru)(ru)從事檢(jian)(jian)修工作(zuo)。■198條 進入(ru)(ru)SF6配電裝置(zhi)室(shi)低(di)位區或電纜溝進行工作(zuo)應(ying)先檢(jian)(jian)測含氧量(liang)(liang)(liang)(不(bu)低(di)于18%)和SF6氣(qi)體含量(liang)(liang)(liang)是否合格(ge)

光伏站sf6泄漏報警器 燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子 光伏站sf6泄漏報警器

燃氣報警器_可燃氣體報警器_可燃氣體探測器_氣體報警控制器_SF6泄漏報警主機_東信電子

地(di)址:濟南市高新(xin)技術(shu)開發區花園路東首

電話:15376190119